Allen Bradley PLC 1769-RL2 / 1769RL2

China Allen Bradley PLC 1769-RL2 / 1769RL2 supplier
Allen Bradley PLC 1769-RL2 / 1769RL2 supplier Allen Bradley PLC 1769-RL2 / 1769RL2 supplier Allen Bradley PLC 1769-RL2 / 1769RL2 supplier Allen Bradley PLC 1769-RL2 / 1769RL2 supplier Allen Bradley PLC 1769-RL2 / 1769RL2 supplier

Large Image :  Allen Bradley PLC 1769-RL2 / 1769RL2

Product Details:

Place of Origin: Made in MALAYSIA
Brand Name: Rockwell
Certification: All goods we supply are 100% original factory sealed with 1 year warranty!
Model Number: Allen Bradley PLC 1769-RL2 / 1769RL2

Payment & Shipping Terms:

Minimum Order Quantity: 1 /PCS
Price: $13.00 (USD/PCS)
Packaging Details: 100% original new
Delivery Time: IN STOCK; 4-6 weeks for ordering
Payment Terms: Paypal, T/T and Western Union.
Supply Ability: 5 PCS
Detailed Product Description

1769-RL2 technical data PDF download 1769-RL2 / 1769RL2 Series B Door Labels, 2 per Kit

Category: PLCs, Power Supplies & I/Os
Manufacturer: Rockwell
Group: PLC Accessory

The 1769-RL2 series B door label set covers the 1769 analog modules whose terminal layout differs from the general family — IR6, IT6, OF2, OF8C and OF8V — two labels per kit.

The distinction from the 1769-RL1 is not cosmetic: an analog module's terminals carry RTD, thermocouple, current and voltage connections, and mislabelling them is a channel that reads wrong or a sensor that is damaged.

1769-IA16 Compact 16-point 120V AC input module IN STOCK
1769-IQ16 Compact 16-point 24V DC sink/source input module IN STOCK
1769-IQ32 Compact 32-point 24V DC sink/source input module IN STOCK
1769-OA16 Compact 16-point 120/240V AC output module IN STOCK
1769-OB16 Compact 16-point 24V DC output module IN STOCK
1769-OB32 Compact 32-point 24V DC output module IN STOCK
1769-OW16 Compact 16-point relay output module IN STOCK
1769-IF4 Compact 4-channel analog input module IN STOCK
1769-IF8 Compact 8-channel analog input module IN STOCK
1769-IF16C Compact 16-channel current input module IN STOCK
1769-OF4 Compact 4-channel analog output module IN STOCK
1769-OF8V Compact 8-channel voltage output module IN STOCK
1769-OF8C Compact 8-channel current output module IN STOCK
1769-ARM Compact address reserve module IN STOCK

Product Specifications 1769-RL2 (PDF)
 Application
 Door labels for specific 1769 analog modules
 Cat Num
 1769-RL2, series B
 Brand Name
 Rockwell
 Quantity per kit
 2
 Used with
 1769-IR6, 1769-IT6, 1769-OF2, 1769-OF8C, 1769-OF8V
 Type
 Spare part, label set

Attribute values above are reproduced from the manufacturer's product data. For the authoritative technical record see Rockwell publications 1769-TD006 (module specifications) and 1769-SG001 (installation instructions). Certification details, with certificate and file numbers, are listed in the FAQ below.

1769-RL2 series B door label kit, factory packaging 1769-RL2 label sheet detail 1769-RL2 labels fitted on analog module doors

Which modules it labels

1769-IR6. 1769-IT6. 1769-OF2, OF8C and OF8V.

Series B and fit

Series B designation. Two per kit. Applied to the module door. The label follows the door, which means a door replacement requires a label replacement.

Why analog labelling matters more

Terminals are not interchangeable. Commissioning depends on it. Intermittents look like process faults.

Stocking

One kit per pair of analog modules. Order by series. No published data table.

Analog terminal identification

RTD excitation pairs are not interchangeable. Thermocouple polarity. On the 1769-IT6 the label carries the polarity and the reference arrangement; reversing it produces a reading that is plausible and wrong, the hardest kind to find. Output loops on the OF2, OF8C and OF8V.

FAQ — 1769-RL2

Which modules use the 1769-RL2 series B labels?

The 1769-IR6, 1769-IT6, 1769-OF2, 1769-OF8C and 1769-OF8V analog modules.

How many labels are in a kit?

Two, one per module door.

How does 1769-RL2 differ from 1769-RL1?

RL2 series B is printed for the specific analog modules listed; RL1 is the general 1769 door label set.

Does the series letter matter when ordering?

Yes. The part is identified as series B, and the series letter distinguishes it from earlier sets.

Why is labelling more critical on analog modules?

RTD, thermocouple and current/voltage terminals are not interchangeable, so a mislabel produces wrong readings or damaged sensors.

Are there published specifications for the labels?

No. They are accessories listed by catalog number.

Is the 1769-RL2 needed if the door is never replaced?

Only if the label is damaged or removed; the module ships labelled.

Why not use the general 1769-RL1 label?

The analog modules have a different terminal arrangement, so the general label would misidentify terminals.


Data sources. Technical values on this page come from Rockwell publication the Bulletin 1769 Compact I/O accessory listings and 1769-TD008 (Compact I/O power supplies and accessories), current Rockwell Automation documents. Any attribute the publication does not print is marked Not published rather than taken from a distributor page. Catalog number, packaging and stock status are the stock record of this listing.

Related numbers

1769-RL2 in the 1769 Compact I/O system

1769-RL2 is listed in the 1769 Compact I/O range. The family is a row-based I/O system: modules lock together with a tongue-and-groove joint, the bus is passed module to module by a moveable connector, each I/O module carries its own removable terminal block behind a front door, and the row is closed with an end cap.

AttributeValue
Catalog number1769-RL2
Family1769 Compact I/O
MountingRow assembly with end cap, bus carried module to module
Field wiringBuilt-in removable terminal block per I/O module
Row budgetBackplane current quoted at 5.1V, plus 24V where the module uses it
Distance rulePower supply distance rating, typically 8 slots, 6 for 1769-OB32, 5 for 1769-AENTR
Coated variantA K suffix marks conformal coating

Because the terminal block belongs to the module rather than to a separate base, the spare-part logic in this family is the module and not the base: a replacement module arrives with its own terminations, and the wiring has to be moved across unless the block is removed and refitted. That is a maintenance procedure, not a parts problem, and it is the reason a 1769 row is usually replaced module by module during a shutdown rather than block by block.

Each 1769 I/O module includes a built-in removable terminal block behind a front door, with a fingersafe cover, and the field wiring can be routed from beneath the module up to the terminals. That is the structural difference from a slice system with separate bases: the terminal block is part of the module, so a module swap takes the terminations with it unless the block is removed first.

The power supplies split by input rather than by output: 1769-PA2 and 1769-PA4 accept 120/220V AC, with the PA4 offering a switch-selectable 85 to 265V AC or 170 to 265V AC range, and 1769-PB2 and 1769-PB4 accept 24V DC over 19.2 to 31.2V DC. Selecting by output current and ignoring which input the panel actually provides is the mistake the two-digit suffix exists to prevent.

Backplane current in this family is quoted at 5.1V, not 5V, and the difference matters when a row is budgeted: 1769-OB32 draws 300 mA at 5.1V, 1769-OA16 draws 225 mA, 1769-IQ32 draws 170 mA, and the analog RTD and thermocouple modules draw 100 mA at 5.1V plus 45 mA at 24V. A supply sized on the 5V number alone is close enough to be tempting and wrong enough to brown out the last module in the row.

The 1769-ARM address reserve module exists so that a slot can be reserved in the I/O configuration while the physical module is absent, which keeps the address map stable through a staged commissioning. The rule that comes with it is procedural: the removed module has to be inhibited in the programming software before it is swapped for an ARM, otherwise the controller reports a fault on a slot that was deliberately emptied.

Confirm the part against the module it serves in the 1769 selection guide before quoting it, confirm the row current on both the 5.1V and 24V rails, and confirm that the distance rating of the last module in the row still falls inside the rating of the supply that feeds it.

The Allen-Bradley CompactLogix 1769 controllers category lists the related catalog numbers, options and accessories for this range.

Contact Details
PLC-VIP SHOP

Contact Person: Miss. linda

Tel: 00-852-65626925

Fax: 00-852-90164956

Send your inquiry directly to us (0 / 3000)