Product Details:
Payment & Shipping Terms:
|
The 1769-RL1 is the door label kit for 1769 Compact I/O modules, two labels per kit — the printed strip that identifies the module's terminals on its access door.
It is a documentation part rather than a functional one, and that is exactly why it matters: a module without its label is a module whose terminals have to be identified from a drawing at the worst possible moment.
| 1769-IA16 | Compact 16-point 120V AC input module | IN STOCK |
| 1769-IQ16 | Compact 16-point 24V DC sink/source input module | IN STOCK |
| 1769-IQ32 | Compact 32-point 24V DC sink/source input module | IN STOCK |
| 1769-OA16 | Compact 16-point 120/240V AC output module | IN STOCK |
| 1769-OB16 | Compact 16-point 24V DC output module | IN STOCK |
| 1769-OB32 | Compact 32-point 24V DC output module | IN STOCK |
| 1769-OW16 | Compact 16-point relay output module | IN STOCK |
| 1769-IF4 | Compact 4-channel analog input module | IN STOCK |
| 1769-IF8 | Compact 8-channel analog input module | IN STOCK |
| 1769-IF16C | Compact 16-channel current input module | IN STOCK |
| 1769-OF4 | Compact 4-channel analog output module | IN STOCK |
| 1769-OF8V | Compact 8-channel voltage output module | IN STOCK |
| 1769-OF8C | Compact 8-channel current output module | IN STOCK |
| 1769-ARM | Compact address reserve module | IN STOCK |
Application |
Replacement door labels, 1769 Compact I/O modules |
Cat Num |
1769-RL1 |
Brand Name |
Rockwell |
Quantity per kit |
2 |
Type |
Spare part, label set |
Attribute values above are reproduced from the manufacturer's product data. For the authoritative technical record see Rockwell publications 1769-TD006 (module specifications) and 1769-SG001 (installation instructions). Certification details, with certificate and file numbers, are listed in the FAQ below.
What is the 1769-RL1?
A door label kit for 1769 Compact I/O modules, two labels per kit.
How many labels come in the kit?
Two, one per module door.
What is the difference between 1769-RL1 and 1769-RL2?
RL1 is the general label set for the 1769 family; RL2 series B is listed for specific analog modules such as IR6, IT6, OF2, OF8C and OF8V.
Does a replaced door need a new label?
Yes. A 1769-RD door fitted without its label leaves the terminals unidentified.
Are the labels adhesive?
Yes, they are applied to the module door.
Do labels affect module operation?
No. They are documentation only, but they determine whether field wiring can be identified without the drawing.
Do the labels carry terminal numbers?
Yes, the label identifies the terminals of the module it is printed for.
Why would a label need replacing?
Door replacement, cleaning, or adhesive failure — all routine over the life of a panel.
1769-RL1 is listed in the 1769 Compact I/O range. The family is a row-based I/O system: modules lock together with a tongue-and-groove joint, the bus is passed module to module by a moveable connector, each I/O module carries its own removable terminal block behind a front door, and the row is closed with an end cap.
| Attribute | Value |
| Catalog number | 1769-RL1 |
| Family | 1769 Compact I/O |
| Mounting | Row assembly with end cap, bus carried module to module |
| Field wiring | Built-in removable terminal block per I/O module |
| Row budget | Backplane current quoted at 5.1V, plus 24V where the module uses it |
| Distance rule | Power supply distance rating, typically 8 slots, 6 for 1769-OB32, 5 for 1769-AENTR |
| Coated variant | A K suffix marks conformal coating |
Because the terminal block belongs to the module rather than to a separate base, the spare-part logic in this family is the module and not the base: a replacement module arrives with its own terminations, and the wiring has to be moved across unless the block is removed and refitted. That is a maintenance procedure, not a parts problem, and it is the reason a 1769 row is usually replaced module by module during a shutdown rather than block by block.
The K suffix in this range means conformal coating, and it is applied across the whole family rather than to a single module: 1769-IA8K, 1769-IQ16K, 1769-OB16K and 1769-PA2K are the coated equivalents of their plain counterparts. In a corrosive or condensing environment the coated variant is the specification, and the plain part is not made acceptable by adding a cabinet heater.
Backplane current in this family is quoted at 5.1V, not 5V, and the difference matters when a row is budgeted: 1769-OB32 draws 300 mA at 5.1V, 1769-OA16 draws 225 mA, 1769-IQ32 draws 170 mA, and the analog RTD and thermocouple modules draw 100 mA at 5.1V plus 45 mA at 24V. A supply sized on the 5V number alone is close enough to be tempting and wrong enough to brown out the last module in the row.
Analog and temperature modules in this family carry a second rail: the 1769-IR6 and 1769-IT6 take 100 mA at 5.1V and 45 mA at 24V, so a row that mixes them with digital I/O has to be checked on both rails. The 24V figure is small in absolute terms and still disqualifying when the 24V budget was calculated from digital modules that draw nothing from it.
The 1769 architecture is a bus that travels through the modules rather than a backplane that carries them: the modules mechanically lock together with a tongue-and-groove joint and the communication bus is passed from module to module by a moveable connector. That is why a 1769 assembly is built as a row with an end cap, and why the order of the modules is a wiring decision as well as a programming one.
Confirm the part against the module it serves in the 1769 selection guide before quoting it, confirm the row current on both the 5.1V and 24V rails, and confirm that the distance rating of the last module in the row still falls inside the rating of the supply that feeds it.
Other catalog numbers and accessories for the same range are collected in the Allen-Bradley CompactLogix 1769 controllers category.