Product Details:
Payment & Shipping Terms:
|
The 1769-RD is the replacement access door for 1769 Compact I/O modules, supplied two per kit and covering one slot width.
It is the plastic cover that sits over the terminal blocks: a small part, but a missing door leaves live terminals exposed, which is an inspection finding and a safety issue in any panel.
| 1769-IA16 | Compact 16-point 120V AC input module | IN STOCK |
| 1769-IQ16 | Compact 16-point 24V DC sink/source input module | IN STOCK |
| 1769-IQ32 | Compact 32-point 24V DC sink/source input module | IN STOCK |
| 1769-OA16 | Compact 16-point 120/240V AC output module | IN STOCK |
| 1769-OB16 | Compact 16-point 24V DC output module | IN STOCK |
| 1769-OB32 | Compact 32-point 24V DC output module | IN STOCK |
| 1769-OW16 | Compact 16-point relay output module | IN STOCK |
| 1769-IF4 | Compact 4-channel analog input module | IN STOCK |
| 1769-IF8 | Compact 8-channel analog input module | IN STOCK |
| 1769-IF16C | Compact 16-channel current input module | IN STOCK |
| 1769-OF4 | Compact 4-channel analog output module | IN STOCK |
| 1769-OF8V | Compact 8-channel voltage output module | IN STOCK |
| 1769-OF8C | Compact 8-channel current output module | IN STOCK |
| 1769-ARM | Compact address reserve module | IN STOCK |
Application |
Replacement terminal block access door, 1769 modules |
Cat Num |
1769-RD |
Brand Name |
Rockwell |
Quantity per kit |
2 |
Slot width |
1 slot |
Type |
Spare part, plastic door |
Attribute values above are reproduced from the manufacturer's product data. For the authoritative technical record see Rockwell publications 1769-TD006 (module specifications) and 1769-SG001 (installation instructions). Certification details, with certificate and file numbers, are listed in the FAQ below.
What is the 1769-RD?
A replacement access door for 1769 Compact I/O modules, supplied two per kit.
How many doors are in a kit?
Two, each covering one slot width.
Does the door have an electrical function?
No. It covers the terminal blocks and keeps the module finger-safe.
Why is a missing door a problem?
It leaves live terminals exposed, which is a safety and inspection finding.
How many kits should be kept in stock?
Enough to cover the modules in a panel plus one spare kit; they are inexpensive and commonly lost.
Can the door be fitted without removing the module?
Yes, the door fits over the terminal area of the module in place.
How many doors does the kit contain?
Two, each covering one slot width.
Does a missing door affect module operation?
No. It affects finger safety and inspection compliance, not the electrical function.
1769-RD is listed in the 1769 Compact I/O range. The family is a row-based I/O system: modules lock together with a tongue-and-groove joint, the bus is passed module to module by a moveable connector, each I/O module carries its own removable terminal block behind a front door, and the row is closed with an end cap.
| Attribute | Value |
| Catalog number | 1769-RD |
| Family | 1769 Compact I/O |
| Mounting | Row assembly with end cap, bus carried module to module |
| Field wiring | Built-in removable terminal block per I/O module |
| Row budget | Backplane current quoted at 5.1V, plus 24V where the module uses it |
| Distance rule | Power supply distance rating, typically 8 slots, 6 for 1769-OB32, 5 for 1769-AENTR |
| Coated variant | A K suffix marks conformal coating |
Because the terminal block belongs to the module rather than to a separate base, the spare-part logic in this family is the module and not the base: a replacement module arrives with its own terminations, and the wiring has to be moved across unless the block is removed and refitted. That is a maintenance procedure, not a parts problem, and it is the reason a 1769 row is usually replaced module by module during a shutdown rather than block by block.
The 1769 architecture is a bus that travels through the modules rather than a backplane that carries them: the modules mechanically lock together with a tongue-and-groove joint and the communication bus is passed from module to module by a moveable connector. That is why a 1769 assembly is built as a row with an end cap, and why the order of the modules is a wiring decision as well as a programming one.
Backplane current in this family is quoted at 5.1V, not 5V, and the difference matters when a row is budgeted: 1769-OB32 draws 300 mA at 5.1V, 1769-OA16 draws 225 mA, 1769-IQ32 draws 170 mA, and the analog RTD and thermocouple modules draw 100 mA at 5.1V plus 45 mA at 24V. A supply sized on the 5V number alone is close enough to be tempting and wrong enough to brown out the last module in the row.
Analog and temperature modules in this family carry a second rail: the 1769-IR6 and 1769-IT6 take 100 mA at 5.1V and 45 mA at 24V, so a row that mixes them with digital I/O has to be checked on both rails. The 24V figure is small in absolute terms and still disqualifying when the 24V budget was calculated from digital modules that draw nothing from it.
Each 1769 I/O module includes a built-in removable terminal block behind a front door, with a fingersafe cover, and the field wiring can be routed from beneath the module up to the terminals. That is the structural difference from a slice system with separate bases: the terminal block is part of the module, so a module swap takes the terminations with it unless the block is removed first.
Confirm the part against the module it serves in the 1769 selection guide before quoting it, confirm the row current on both the 5.1V and 24V rails, and confirm that the distance rating of the last module in the row still falls inside the rating of the supply that feeds it.
This part sits in the Allen-Bradley CompactLogix 1769 controllers category, with the other models and spare parts listed alongside it.