Product Details:
Payment & Shipping Terms:
|
The 1769-CLL1 is a Compact I/O expansion cable, left bank to left bank, 305 mm (1 ft), used to extend the 1769 backplane between two banks of modules.
It carries bus communication and nothing else. That single fact drives the whole specification: a 1769 system takes at most two expansion cables, giving three groups of modules, and each additional bank needs its own 1769-PA2, -PB2, -PA4 or -PB4 power supply.
The 1769-CLL1 and 1769-CLL3 are the same cable in different lengths — 305 mm (1 ft) against 1 m (3.28 ft), 350 g — so the choice is a layout decision, not an electrical one.
| 1769-IA16 | Compact 16-point 120V AC input module | IN STOCK |
| 1769-IQ16 | Compact 16-point 24V DC sink/source input module | IN STOCK |
| 1769-IQ32 | Compact 32-point 24V DC sink/source input module | IN STOCK |
| 1769-OA16 | Compact 16-point 120/240V AC output module | IN STOCK |
| 1769-OB16 | Compact 16-point 24V DC output module | IN STOCK |
| 1769-OB32 | Compact 32-point 24V DC output module | IN STOCK |
| 1769-OW16 | Compact 16-point relay output module | IN STOCK |
| 1769-IF4 | Compact 4-channel analog input module | IN STOCK |
| 1769-IF8 | Compact 8-channel analog input module | IN STOCK |
| 1769-IF16C | Compact 16-channel current input module | IN STOCK |
| 1769-OF4 | Compact 4-channel analog output module | IN STOCK |
| 1769-OF8V | Compact 8-channel voltage output module | IN STOCK |
| 1769-OF8C | Compact 8-channel current output module | IN STOCK |
| 1769-ARM | Compact address reserve module | IN STOCK |
Application |
Compact I/O, 1769 bus |
Cat Num |
1769-CLL1 |
Brand Name |
Rockwell |
Function |
Extends the 1769 backplane communication lines between two banks |
Orientation |
Left bank to left bank, 305 mm (1 ft) |
Length |
305 mm (1 ft) |
Weight, approx |
300 g |
Cables per system, max |
2 (three banks maximum) |
Power carried |
Bus communication only; each bank needs its own supply |
Attribute values above are reproduced from the manufacturer's product data. For the authoritative technical record see Rockwell publications 1769-TD006 (module specifications) and 1769-SG001 (installation instructions). Certification details, with certificate and file numbers, are listed in the FAQ below.
What does 1769-CLL1 do?
It extends the 1769 backplane communication between two banks of Compact I/O modules over 305 mm (1 ft).
How long is 1769-CLL1?
305 mm (1 ft), weighing approximately 300 g.
How many 1769-CLL1 cables can one system use?
Two expansion cables in total, which allows three banks of I/O modules.
Does 1769-CLL1 carry power to the next bank?
No. It carries bus communication only, so each bank needs its own 1769-PA2, -PB2, -PA4 or -PB4 supply.
What is the difference between 1769-CLL1 and 1769-CLL3?
Length only: 305 mm (1 ft) against 1 m (3.28 ft), 350 g; the electrical function is identical.
What must be fitted to the ends left open by 1769-CLL1?
End caps — 1769-ECL at the left end and 1769-ECR at the right end — otherwise the backplane stays open.
The expansion hardware is where a CompactLogix system is most often specified wrongly, because the cable is a mechanical and an electrical component at once: it sets the distance between banks, and on some of them it also carries power. The rows below are the published set for this family.
| Catalog | Function | Orientation | Power carried | Max per system |
|---|---|---|---|---|
| 1769-CLL1 | Extends the 1769 backplane communication lines between two banks | Left bank to left bank, 305 mm (1 ft) | Bus communication only; each bank needs its own supply | 2 (three banks maximum) |
| 1769-CLL3 | Extends the 1769 backplane communication lines between two banks | Left bank to left bank, 1 m (3.28 ft) | Bus communication only; each bank needs its own supply | 2 (three banks maximum) |
| 1769-CRL1 | Extends the 1769 backplane communication lines between two banks | Right bank to left bank, 305 mm (1 ft) | Bus communication only; each bank needs its own supply | 2 (three banks maximum) |
| 1769-CRL3 | Extends the 1769 backplane communication lines between two banks | Right bank to left bank, 1 m (3.28 ft) | Bus communication only; each bank needs its own supply | 2 (three banks maximum) |
| 1769-CRR1 | Extends the 1769 backplane communication lines between two banks | Right bank to right bank, 305 mm (1 ft) | Bus communication only; each bank needs its own supply | 2 (three banks maximum) |
| 1769-CRR3 | Extends the 1769 backplane communication lines between two banks | Right bank to right bank, 1 m (3.28 ft) | Bus communication only; each bank needs its own supply | 2 (three banks maximum) |
| 1769-ECL | Terminates the bus at the far end of an I/O bank | Not published | Not published | Not published |
| 1769-ECR | Terminates the bus at the far end of an I/O bank | Not published | Not published | Not published |
Two rules come out of this table and neither is visible from a catalog number alone. The first is that a cable has an orientation - left or right of the controller - so a spare ordered by length rather than by part can arrive unable to reach the bank it was meant for. The second is the per-system limit, which caps how many banks can be chained before the topology has to change rather than be extended.
Where the cable carries power, the length is an electrical limit as well as a mechanical one: the 5V rail is regulated at the supply and not at the far end, so a long run spends headroom that a short one does not. That is why the end caps and the distance rating appear in the same section of the publication as the cables.
An end cap is not optional hardware. Each bank terminates with one, and a bank built without it is a bus that reads low or not at all — the failure looks like a dead module rather than like a missing terminator.
1769-CLL1 is the catalog number this page is filed under. The table above is the shared family data for the group, reproduced here so the row next to this code can be checked in place.
This part sits in the Allen-Bradley CompactLogix 1769 controllers category, with the other models and spare parts listed alongside it.