Product Details:
Payment & Shipping Terms:
|
1761-HHP-B30 is the Hand-Held Programmer: Hand-held programmer for the MicroLogix 1000.
The unit is a pocket terminal: a display, a keypad and a serial connector, with no PC required.
The hand-held route existed because a MicroLogix 1000 panel often had no room for a laptop and no network to reach. A pocket terminal with a memory module was enough to load a program and read a fault.
| 1761-HHP-B30 | Hand-Held Programmer | IN STOCK |
| 1761-HHM-K64 | 64 KB Handheld Memory Module | IN STOCK |
| 1761-HHM-K08 | 8 KB Handheld Memory Module | IN STOCK |
Catalog number |
1761-HHP-B30 |
Description |
Hand-held programmer for the MicroLogix 1000 |
Used with |
MicroLogix 1000 controllers and the 1761 hand-held programmer |
Lifecycle status |
Discontinued July 31, 2013 |
Replacement category |
No planned RA replacement |
UPC |
Not published |
Temperature rating |
0…55 °C where Rockwell publishes it |
Country of origin |
Singapore on the 64 KB module |
Publication |
1761-UM003 |
Attribute values above are reproduced from the manufacturer's product data. For the authoritative technical record see Rockwell publications 1761-UM003 (module specifications) and 1761-SG001 (installation instructions). Certification details, with certificate and file numbers, are listed in the FAQ below.
Hand-held programmer for the MicroLogix 1000.
The unit is a pocket terminal: a display, a keypad and a serial connector, with no PC required.
The programmer and the memory modules were sold as a set. A program was prepared on a PC, copied to the module, and the module carried into the panel — the module, not the terminal, was the thing that travelled.
Connect the terminal to the controller's RS-232 programming port with the 1761-CBL-HM02 cable, select the memory module as the source, and transfer. No software, no driver, no address to set.
For a maintenance visit the sequence was: read the fault, read the program revision, load the archived program from the module, restart. Everything needed fit in a coat pocket, which is why the parts survived in tool bags long after the platform was replaced.
Rockwell publishes 64 KB of memory for the 1761-HHM-K64 module, with a 0…55 °C temperature rating and Singapore as the country of origin. The 8 KB module carries the same function at a smaller capacity; its current product page is no longer published, so no figure is restated for it here.
Memory modules are static parts. They do not lose content with age the way a battery-backed RAM does, but they are sensitive to handling — a module stored loose in a drawer with other boards is a module at risk.
Both the terminal and the modules are out of production, so what is traded is new old stock and pulls. Check the module capacity against the program size before buying: a 1 KB program fits an 8 KB module, but a heavily loaded 1761-L32BWA program with a large data table may not.
The terminal's keypad and display are the parts that fail with use. A unit with a clean display and no missing key legends is the better buy even at a higher price.
1761-HHP-B30 was discontinued on July 31, 2013, with No planned RA replacement as the replacement category.
There is no like-for-like successor. The function moved to PC software: RSLogix 500 over a 1761-CBL-PM02 cable, later Connected Components Workbench on the Micro800 platform.
What is 1761-HHP-B30?
Hand-held programmer for the MicroLogix 1000.
What is 1761-HHP-B30 used with?
MicroLogix 1000 controllers and the 1761 hand-held programmer.
What cable connects the hand-held programmer to a controller?
1761-CBL-HM02.
Is 1761-HHP-B30 still available from Rockwell?
No. Discontinued July 31, 2013.
What replaced the hand-held programmer?
PC software: RSLogix 500 over 1761-CBL-PM02, then Micro800 with CCW.
1761-HHP-B30 is the hand held programmer in the MicroLogix 1000 accessory family. The controller itself is the packaged unit with supply, inputs, outputs and processor in one housing; everything in this family is what connects to it, powers a network segment from it, or carries its program away from it.
| Attribute | Value |
| Catalog number | 1761-HHP-B30 |
| Product type | hand held programmer |
| Family | MicroLogix 1000 accessories, bulletin 1761 |
| Product type | Hand held programmer for MicroLogix 1000 controllers |
| Supplied cable | 1761-CBL-HM02, 2.00 m (6.56 ft) DIN to DIN, included with the programmer |
| Program storage | Uses 1761-HHM-K08 or 1761-HHM-K64 memory modules in the programmer body |
| Door part | 1761-RPL-TRM memory module door, one per package |
| Network limit | Cannot be connected to the 1761-NET-AIC advanced interface converter |
| Function | Monitor and develop control logic programs on the controller |
| Manual | MicroLogix 1000 with Hand Held Programmer, publication 1761-6.2 |
The programmer is a field device rather than a spare: it connects to the controller 8-pin mini-DIN port with the cable shipped in the box, reads and writes the ladder program, and can carry a program in its own memory module so that the same logic can be loaded into several identical machines without a laptop on site.
The family is discontinued in stages, and the documentation follows: the DNI manual has been withdrawn from the literature site while the AIC+ and ENI manuals are still published. When a catalog number is quoted against an obsolete network, read the manual revision before promising compatibility with a current controller series.
The 8-pin mini-DIN port is the common thread through the whole accessory family: the programmer, the AIC+ port 2, the ENI port 2 and the DNI port 2 all speak through it, and the difference between the cables is only the far end and the length. A 45 cm cable is an inside the panel part, a 2 m cable is a reach across the floor, and a D-shell end is what goes to a computer or an SLC channel 0.
Converter supplies are not interchangeable in the paperwork: the AIC+ is rated 20.4 to 28.8V dc with 104 to 120 mA draw and 200 mA inrush, the ENI 20.4 to 26.4V dc with 50 mA typical and 100 mA maximum, and the DNI takes 11 to 25V dc from the DeviceNet connector with 200 mA at 24V dc. A 24V dc supply shared across all three has to be sized on the inrush, not on the steady state.
MicroLogix 1000 controllers store the program in 1K EEPROM, approximately 737 instruction words and 437 data words, and keep 24V dc user supply at 200 mA maximum. Any accessory that appears to add controller memory has to be read carefully, because the 1761-HHM modules belong to the hand held programmer and do not enlarge the controller.
Class I Division 2 installations restrict which cable may be used, and the restriction is stated per catalog number with a series letter: the programming cables have to be series C or later to be used in a hazardous environment. A general purpose cable of the same length is not the same part for that location.
Before ordering, confirm the catalog number against the port it has to reach, confirm the series letter where the installation is in a classified area, and confirm the supply budget of the panel against the current the device draws at 24V dc.
Related models, options and spare parts for this range are listed in the Allen-Bradley MicroLogix 1000 1761 controllers category.