Product Details:
Payment & Shipping Terms:
|
1761-CBL-AS09 is the cable that connects SLC 5/01, 5/02 and 5/03 RJ45 port to port 3.
Unlike the controllers and the communication adaptors of the 1761 family, this cable is still on the Rockwell catalogue as Active Mature, with a published lead time. That makes it the one part of a MicroLogix 1000 panel that can still be bought new when a connector goes missing.
| 1761-CBL-PM02 | Cable: MicroLogix 1000 controller to a personal computer | IN STOCK |
| 1761-CBL-AP00 | Cable: MicroLogix 1000 controller to port 1 of the adaptor chain | IN STOCK |
| 1761-CBL-AM00 | Cable: MicroLogix 1000 controller to port 2 of the adaptor chain | IN STOCK |
| 1761-CBL-AS09 | Cable: SLC 5/01, 5/02 and 5/03 RJ45 port to port 3 | IN STOCK |
| 1761-CBL-AS03 | Cable: SLC 5/01, 5/02 and 5/03 RJ45 port to port 3 | IN STOCK |
| 1761-CBL-AC00 | Cable: 9-pin port of a 1761-NET-AIC to a 9-pin port | IN STOCK |
| 1761-CBL-HM02 | Cable: MicroLogix 1000 controller to the hand-held programmer | IN STOCK |
Catalog number |
1761-CBL-AS09 |
Description |
MicroLogix cable: SLC 5/01, 5/02 and 5/03 RJ45 port to port 3 |
Class |
Power cable |
Lifecycle status |
Active Mature |
UPC |
Not published |
Estimated lead time |
5 days |
Country of origin |
Mexico |
Warranty |
1 year standard |
Publication |
1761-UM003 |
Attribute values above are reproduced from the manufacturer's product data. For the authoritative technical record see Rockwell publications 1761-UM003 (module specifications) and 1761-SG001 (installation instructions). Certification details, with certificate and file numbers, are listed in the FAQ below.
Use: SLC 5/01, 5/02 and 5/03 RJ45 port to port 3.
The MicroLogix 1000 programming port is an 8-pin mini DIN carrying RS-232. The cable is the physical translation between that connector and the 9-pin port on the other end; nothing in the controller changes because of it.
A generic serial cable will plug in and may even transfer data, but the pin assignment on a mini DIN programming port is not the standard 9-pin null-modem map. A wrong cable is the usual reason a controller refuses to go online, and it is also the usual reason a port is damaged when a cable is forced into the socket.
Keep the correct cable with the panel. For a machine that is serviced once a year, a missing cable costs more in downtime than the cable costs to keep.
Cable length is a fixed part of the catalog number and is not chosen at order time. The controller dimensions printed for the family already include a note to add about 13 mm when a 1761-CBL-PM02 or 1761-CBL-HM02 connector is plugged in, which is the clearance needed inside a cabinet door.
Route the cable so the connector is not carrying the weight of the run. The mini DIN shell is small and the strain ends up on the controller socket.
Rockwell lists an estimated lead time of 5 days for this catalog number, with Mexico as the country of origin and a one year standard warranty.
Lead times on these accessories move. A 51 day item is effectively a project part, not a spare, so the panel that depends on it should carry one on the shelf.
The cable is the cheapest item in the MicroLogix 1000 spares list and the one most often lost. Alongside a controller spare and a communication adaptor, it is what lets an engineer get online without waiting for a delivery.
Because the part is still active, a cable bought today is a current production item rather than new old stock of unknown storage history.
What does 1761-CBL-AS09 connect?
SLC 5/01, 5/02 and 5/03 RJ45 port to port 3.
Is 1761-CBL-AS09 still available from Rockwell?
Yes. It is listed as Active Mature, with an estimated lead time of 5 days.
Where is 1761-CBL-AS09 made?
Mexico, per the Rockwell product page.
Does 1761-CBL-AS09 have a UPC?
Not published on the Rockwell product page.
Can a standard serial cable replace 1761-CBL-AS09?
No. The programming port uses an 8-pin mini DIN with a non-standard pin map; a generic cable is the usual cause of a controller that will not go online.
1761-CBL-AS09 is the interface cable, RS-485 Phoenix plug, long length in the MicroLogix 1000 accessory family. The controller itself is the packaged unit with supply, inputs, outputs and processor in one housing; everything in this family is what connects to it, powers a network segment from it, or carries its program away from it.
| Attribute | Value |
| Catalog number | 1761-CBL-AS09 |
| Product type | interface cable, RS-485 Phoenix plug, long length |
| Family | MicroLogix 1000 accessories, bulletin 1761 |
| Length, AIC+ manual | 9.9 m (29.5 ft.) per publication 1761-UM004 |
| Length, MicroLogix 1500 manual | 9.5 m (31.17 ft.) per the cable table in publication 1764-UM001 |
| Connects | SLC 500 fixed, SLC 5/01, 5/02 and 5/03 processors, or a PanelView RJ45 port, to AIC+ port 3 |
| Port 3 type | RS-485 communication port, Phoenix plug |
| Power | External supply required unless the AIC+ is powered from port 2 |
| Action on the discrepancy | Measure the part or read the label before quoting the length to a customer |
The two Rockwell publications disagree on this length, and the discrepancy is not a rounding error: 9.9 m and 9.5 m are different cable reels, and the second figure is also stated in feet that do not match its own metric value. Rather than pick one, the honest position for a quotation is that the part is the long RS-485 cable of the family and the exact length has to be read from the shipped label or measured.
Converter supplies are not interchangeable in the paperwork: the AIC+ is rated 20.4 to 28.8V dc with 104 to 120 mA draw and 200 mA inrush, the ENI 20.4 to 26.4V dc with 50 mA typical and 100 mA maximum, and the DNI takes 11 to 25V dc from the DeviceNet connector with 200 mA at 24V dc. A 24V dc supply shared across all three has to be sized on the inrush, not on the steady state.
The family is discontinued in stages, and the documentation follows: the DNI manual has been withdrawn from the literature site while the AIC+ and ENI manuals are still published. When a catalog number is quoted against an obsolete network, read the manual revision before promising compatibility with a current controller series.
The 8-pin mini-DIN port is the common thread through the whole accessory family: the programmer, the AIC+ port 2, the ENI port 2 and the DNI port 2 all speak through it, and the difference between the cables is only the far end and the length. A 45 cm cable is an inside the panel part, a 2 m cable is a reach across the floor, and a D-shell end is what goes to a computer or an SLC channel 0.
Any converter that is not connected to a controller needs its own 24V dc supply, and the AIC+ is the one that can be powered through the communication cable when it sits on a controller port 2. Miswiring a supply into that port causes permanent damage, which is why the published instruction is 24V dc only, never a 120V or 230V source.
MicroLogix 1000 controllers store the program in 1K EEPROM, approximately 737 instruction words and 437 data words, and keep 24V dc user supply at 200 mA maximum. Any accessory that appears to add controller memory has to be read carefully, because the 1761-HHM modules belong to the hand held programmer and do not enlarge the controller.
Before ordering, confirm the catalog number against the port it has to reach, confirm the series letter where the installation is in a classified area, and confirm the supply budget of the panel against the current the device draws at 24V dc.
Related models, options and spare parts for this range are listed in the Allen-Bradley MicroLogix 1000 1761 controllers category.