Product Details:
Payment & Shipping Terms:
|
1761-NET-ENIW is the MicroLogix and SLC Ethernet Adaptor, web-enabled in the 1761 accessory family: Web-enabled member of the same Ethernet adaptor family, superseded directly by another catalog number.
The adaptors were the way a MicroLogix 1000 or a fixed SLC 500 got onto a plant network before Ethernet was built into the controller. They are discontinued, but a large installed base still runs on them, and a spare is often the fastest way to keep a line talking to a SCADA node.
| 1761-NET-ENI | MicroLogix and SLC Ethernet Adaptor | IN STOCK |
| 1761-NET-DNI | MicroLogix and SLC DeviceNet Adaptor | IN STOCK |
| 1761-NET-AIC | AIC+ Advanced Interface Converter | IN STOCK |
| 1761-NET-ENIW | MicroLogix and SLC Ethernet Adaptor, web-enabled | IN STOCK |
Catalog number |
1761-NET-ENIW |
Description |
Web-enabled member of the same Ethernet adaptor family, superseded directly by another catalog number. |
Class |
Signal converters |
Ports |
RS-232 8-pin mini DIN to RJ45 |
Mounting |
Panel or DIN rail, DIN rail power or 24V dc supply |
Isolation |
Communication side isolated from the controller supply |
Lifecycle status |
Discontinued December 31, 2015 |
Replacement category |
Direct Replacement |
UPC |
Not published |
Publication |
1761-UM005 |
Attribute values above are reproduced from the manufacturer's product data. For the authoritative technical record see Rockwell publications 1761-UM005 (module specifications) and 1761-SG001 (installation instructions). Certification details, with certificate and file numbers, are listed in the FAQ below.
Web-enabled member of the same Ethernet adaptor family, superseded directly by another catalog number.
The converter sits between the controller's RS-232 port and the network. It answers on the network side and polls the controller on the serial side, so the controller's own protocol and program are untouched — no ladder edit, no firmware change, just a node that appears on the network.
Ports: RS-232 8-pin mini DIN to RJ45. The serial side is an 8-pin mini DIN on the Ethernet adaptors, which is the same connector the MicroLogix 1000 programming port uses, so the cable that reaches the controller is the same class of part.
The unit is a panel or DIN rail device with its own supply. Keep the serial run short — these adaptors were specified for a cable at the controller, not for a long drop through a cabinet.
The communication side is transformer-isolated from the controller supply, which is what allows an adaptor on a panel whose logic ground is not the same as the network ground. That isolation is the reason the part survives on machines where a bare serial-to-Ethernet bridge would not.
Throughput is bounded by the serial link, not by the network. An adaptor does not make a 1761-L32BWA into a fast Ethernet controller; it makes it reachable. Plan polling rates accordingly, especially where several clients read the same controller.
Commissioning needs the adaptor's own configuration utility and the network parameters: IP address, subnet and, on the DeviceNet members, a node address and baud rate. Record those settings in the panel documentation — a replacement adaptor is useless without them, and the settings live in the adaptor, not in the controller.
A failed adaptor does not stop the machine. The controller keeps scanning its I/O and the local panel keeps working; only the network side goes dark. That makes a spare the cheapest fix, and it is why these parts are still traded.
1761-NET-ENIW was discontinued on December 31, 2015, with Direct Replacement as the replacement category.
For a new installation the answer is a controller with Ethernet on board rather than an adaptor on an RS-232 port. For an existing panel the answer is usually a tested spare or a planned migration of the whole node.
What does 1761-NET-ENIW connect?
Web-enabled member of the same Ethernet adaptor family, superseded directly by another catalog number.
Which controllers does 1761-NET-ENIW work with?
MicroLogix 1000, 1200 and 1500 controllers and fixed SLC 500 processors with an RS-232 port, per the adaptor's own user manual.
What ports does 1761-NET-ENIW provide?
RS-232 8-pin mini DIN to RJ45.
Is 1761-NET-ENIW still available from Rockwell?
No. Discontinued on December 31, 2015; replacement category Direct Replacement.
Does 1761-NET-ENIW need a separate power supply?
Yes, the adaptor is a panel or DIN rail device with its own supply.
1761-NET-ENIW is the Ethernet network interface with web server, ENIW in the MicroLogix 1000 accessory family. The controller itself is the packaged unit with supply, inputs, outputs and processor in one housing; everything in this family is what connects to it, powers a network segment from it, or carries its program away from it.
| Attribute | Value |
| Catalog number | 1761-NET-ENIW |
| Product type | Ethernet network interface with web server, ENIW |
| Family | MicroLogix 1000 accessories, bulletin 1761 |
| Product type | DF1 full-duplex to EtherNet/IP interface with web server capability |
| Difference from ENI | Adds web server capability to the same EtherNet/IP and email functions |
| Port 2 | RS-232, 8-pin mini-DIN, pin 1 24V dc, pin 2 ground, pin 4 RxD, pin 7 TxD |
| Supply | 24V dc, 20.4 to 26.4V dc, 50 mA typical and 100 mA maximum, 200 mA inrush |
| Isolation | 710V dc for one minute |
| Network | 10/100 Base-T, auto negotiate on series C and D |
| SMTP mail service so the controller can send messages to any address on the network |
The web server difference is what separates the two catalog numbers, and it is a remote diagnostics difference rather than a control difference: both units route DF1 messages and both send SMTP mail, but the ENIW exposes a page that a maintenance browser can reach. Where the plant already has an Ethernet switch and no HMI at the panel, that page substitutes for a service visit.
The family is discontinued in stages, and the documentation follows: the DNI manual has been withdrawn from the literature site while the AIC+ and ENI manuals are still published. When a catalog number is quoted against an obsolete network, read the manual revision before promising compatibility with a current controller series.
The 8-pin mini-DIN port is the common thread through the whole accessory family: the programmer, the AIC+ port 2, the ENI port 2 and the DNI port 2 all speak through it, and the difference between the cables is only the far end and the length. A 45 cm cable is an inside the panel part, a 2 m cable is a reach across the floor, and a D-shell end is what goes to a computer or an SLC channel 0.
Converter supplies are not interchangeable in the paperwork: the AIC+ is rated 20.4 to 28.8V dc with 104 to 120 mA draw and 200 mA inrush, the ENI 20.4 to 26.4V dc with 50 mA typical and 100 mA maximum, and the DNI takes 11 to 25V dc from the DeviceNet connector with 200 mA at 24V dc. A 24V dc supply shared across all three has to be sized on the inrush, not on the steady state.
MicroLogix 1000 controllers store the program in 1K EEPROM, approximately 737 instruction words and 437 data words, and keep 24V dc user supply at 200 mA maximum. Any accessory that appears to add controller memory has to be read carefully, because the 1761-HHM modules belong to the hand held programmer and do not enlarge the controller.
Class I Division 2 installations restrict which cable may be used, and the restriction is stated per catalog number with a series letter: the programming cables have to be series C or later to be used in a hazardous environment. A general purpose cable of the same length is not the same part for that location.
Before ordering, confirm the catalog number against the port it has to reach, confirm the series letter where the installation is in a classified area, and confirm the supply budget of the panel against the current the device draws at 24V dc.
The Allen-Bradley MicroLogix 1000 1761 controllers category groups the other catalog numbers, options and spare parts in the same range.