Allen Bradley PLC 1747-C20 / 1747C20 supplier Allen Bradley PLC 1747-C20 / 1747C20 supplier Allen Bradley PLC 1747-C20 / 1747C20 supplier Allen Bradley PLC 1747-C20 / 1747C20 supplier Allen Bradley PLC 1747-C20 / 1747C20 supplier Allen Bradley PLC 1747-C20 / 1747C20 supplier Allen Bradley PLC 1747-C20 / 1747C20 supplier Allen Bradley PLC 1747-C20 / 1747C20 supplier Allen Bradley PLC 1747-C20 / 1747C20 supplier Allen Bradley PLC 1747-C20 / 1747C20 supplier

Large Image :  Allen Bradley PLC 1747-C20 / 1747C20

Product Details:

Place of Origin: Made in USA
Brand Name: PLC Module
Certification: All goods we supply are 100% original factory sealed with 1 year warranty!
Model Number: Allen Bradley PLC 1747-C20 / 1747C20

Payment & Shipping Terms:

Minimum Order Quantity: 1 /PCS
Price: $57.00 (USD/PCS)
Packaging Details: 100% original new
Delivery Time: IN STOCK; 4-6 weeks for ordering
Payment Terms: Paypal, T/T and Western Union.
Supply Ability: 1-5 PCS
Detailed Product Description

1747-C20 technical data PDF download 1747-C20 SLC Replacement Cable

Category: PLCs, Power Supplies & I/Os
Manufacturer: Rockwell
Group: SLC 500 System 1747

1747-C20 is a SLC Replacement Cable, 6.09 m (20 ft) long, used for: Processor to peripheral programming/communication port over a longer run; data table access module.

Rockwell discontinued the catalog number on 2022-12-31, replacement category No planned RA replacement.

1747-C10 SLC Replacement Cable 1.8 m (6 ft) IN STOCK
1747-C11 SLC Replacement Cable 304.8 mm (12 in) IN STOCK
1747-C13 SLC Cable 914.4 mm (36 in) IN STOCK
1747-C20 SLC Replacement Cable 6.09 m (20 ft) IN STOCK
1747-CP3 SLC 5/03 Programmer RS-232 Cable 3.96 m (12 ft), two 9-pin DTE connectors IN STOCK

Product Specifications 1747-C20 (PDF)
 Catalog number
 1747-C20
 Description
 SLC Replacement Cable
 Length
 6.09 m (20 ft)
 Used for
 Processor to peripheral programming/communication port over a longer run; data table access module
 Operating temperature
 0…60 °C (32…140 °F)
 Discontinued date
 2022-12-31
 Replacement category
 No planned RA replacement
 Replacement product
 None published
 Publication
 1747-UM011

1747-C20 (SLC 500 programming / network cable, 6.09 m (20 ft)): it the long variant of the processor-to-peripheral programming cable, used to reach the interface converter or the Data Table Access Module from a PC that is not beside the cabinet.

When to choose it: Buy it when the distance is real - a programming station at the end of a line, or a DTAM on the machine rather than in the panel. It is the same cable as 1747-C10 apart from length, so the choice between them is a layout decision, not an electrical one. A wrong cable in this position looks like a dead port rather than a wrong cable, so match the catalogue number to the port first. Source: Rockwell publication 1747-UM011, replacement cables and connectors section.

Attribute values above are reproduced from the manufacturer's product data. For the authoritative technical record see Rockwell publications 1747-UM011 (module specifications) and 1747-UM011 (installation instructions). Certification details, with certificate and file numbers, are listed in the FAQ below.

Part Description: 1747-C20 SLC Replacement Cable
1747-C20 1747-C20 1747-C20

What the cable connects

Processor to peripheral programming/communication port over a longer run; data table access module. The length is the part that matters: in a panel the run between the processor port and the device it serves is fixed by the enclosure layout, and a cable that is too short forces the hardware to move.

Rockwell prints the cable lengths in the replacement cables and connectors table of 1747-UM011, which is the source used here. A distributor listing that quotes a different length for the same catalog number is quoting a different item.

Where it fits in the SLC 500 wiring scheme

Programming and DH-485 cabling in an SLC 500 system is a short list: a processor-to-peripheral cable, a processor-to-isolated-link-coupler cable, a communication-module-to-coupler cable, and the RS-232 programmer cable for channel 0 on the 5/03 and later.

This catalog number is one of those four roles. Getting the role wrong is the usual wiring fault: a cable that reaches the right connector but carries the wrong pinout will either not communicate or will communicate intermittently.

Pinout, connectors and handling

The RS-232 programmer cable carries two 9-pin DTE connectors and is wired for the SLC channel 0 port. The DH-485 cables carry the connector that matches the isolated link coupler and the processor or module port they serve.

Cables are wear items at a programming port that is used every shift. Keep one spare of the cable actually in use; a replacement with a different length or connector will not substitute in the same panel.

Buying a discontinued cable

Check the connector types at both ends against the ports in the panel, check the printed length on the cable jacket, and check continuity pin by pin before the cable goes into service. A cable that has been coiled tight in a drawer for a decade can look perfect and fail on one conductor.

Rockwell's replacement category for this catalog number is No planned RA replacement.

Lifecycle status

Discontinued 2022-12-31. Cable catalog numbers in the 1747 family were withdrawn in several waves between 2013 and 2024; this one left the catalogue on that date.

For a plant that still runs SLC 500, the cable is a stock item rather than a project item: buy tested spares while they are available, because the pinouts are specific to this platform.

FAQ — 1747-C20

How long is 1747-C20?

6.09 m (20 ft).

What does 1747-C20 connect?

Processor to peripheral programming/communication port over a longer run; data table access module.

Is 1747-C20 still available from Rockwell?

No. Discontinued 2022-12-31, replacement category No planned RA replacement.

Can another cable be substituted?

Only with the same connector types and pinout. Length alone is not the specification.

What temperature range is published for 1747-C20?

0…60 °C (32…140 °F).


Data sources. Lengths and the port each cable serves are printed in the replacement cables and connectors table of 1747-UM011. Lifecycle dates come from the Rockwell product page of the catalog number. Any attribute a publication does not print is marked Not published rather than taken from a distributor page. Catalog number, packaging and stock status are the stock record of this listing.

The 1747 cable set: length and destination are the whole difference

Five cables cover the whole 1747 cabling question and the only figures that separate them are length and what they reach: 304.8 mm from a processor to a link coupler at one end, 6.09 m from a processor to a peripheral at the other.

CableLengthWhat it reaches
1747-C101.8 m (6 ft)Processor to peripheral programming/communication port; also hand-held terminal and data table access module
1747-C11304.8 mm (12 in)Processor to 1747-AIC isolated link coupler
1747-C13914.4 mm (36 in)Communication module (1746-BAS, 1747-KE, 1747-UIC) to 1747-AIC isolated link coupler
1747-C206.09 m (20 ft)Processor to peripheral programming/communication port over a longer run; data table access module
1747-CP33.96 m (12 ft), two 9-pin DTE connectorsSLC 5/03, 5/04, 5/05 channel 0 RS-232 to a personal computer serial port

Where this cable sits: 1747-C20 is printed at 6.09 m (20 ft), and it reaches Processor to peripheral programming/communication port over a longer run; data table access module. The five cables run from 304.8 mm to 6.09 m, so this one is the short end of the set: length and destination are the only two figures that separate them.

Lengths are printed, pinouts are not: the 1747-CP3 is a two-9-pin DTE cable for channel 0 of a 5/03, 5/04 or 5/05, while the C10, C11, C13 and C20 are the shorter link cables. None of these substitutes for another, and the length is the only figure that decides which one reaches.

Source: Rockwell 1747-IN009, 1747-IN007, 1747-IN019, 1747-IN062, 1747-UM011 and 1747-RM001 as recorded per catalog number, plus the Rockwell product page for each number. Every figure is quoted as printed; no value is calculated.