Product Details:
Payment & Shipping Terms:
|
1747-C13 is a SLC Cable, 914.4 mm (36 in) long, used for: Communication module (1746-BAS, 1747-KE, 1747-UIC) to 1747-AIC isolated link coupler.
Rockwell discontinued the catalog number on 2024-09-30, replacement category No planned RA replacement.
| 1747-C10 | SLC Replacement Cable 1.8 m (6 ft) | IN STOCK |
| 1747-C11 | SLC Replacement Cable 304.8 mm (12 in) | IN STOCK |
| 1747-C13 | SLC Cable 914.4 mm (36 in) | IN STOCK |
| 1747-C20 | SLC Replacement Cable 6.09 m (20 ft) | IN STOCK |
| 1747-CP3 | SLC 5/03 Programmer RS-232 Cable 3.96 m (12 ft), two 9-pin DTE connectors | IN STOCK |
Catalog number |
1747-C13 |
Description |
SLC Cable |
Length |
914.4 mm (36 in) |
Used for |
Communication module (1746-BAS, 1747-KE, 1747-UIC) to 1747-AIC isolated link coupler |
Operating temperature |
0…60 °C (32…140 °F) |
Discontinued date |
2024-09-30 |
Replacement category |
No planned RA replacement |
Replacement product |
None published |
Publication |
1747-UM011 |
1747-C13 (SLC 500 programming / network cable, 914.4 mm (36 in)): it connects communication modules - 1746-BAS, 1747-KE, 1747-UIC - to the isolated link coupler, and the coupler itself must be powered from an external supply or reached through a 1747-C10/1747-C11 chain.
When to choose it: 36 in is the length that reaches from a communication module slot to the AIC mounted at the side of the chassis. Both the electrical rule and the length matter: an AIC on this cable cannot borrow power from the module, it needs its own 24 V supply. A wrong cable in this position looks like a dead port rather than a wrong cable, so match the catalogue number to the port first. Source: Rockwell publication 1747-UM011, replacement cables and connectors section.
Attribute values above are reproduced from the manufacturer's product data. For the authoritative technical record see Rockwell publications 1747-UM011 (module specifications) and 1747-UM011 (installation instructions). Certification details, with certificate and file numbers, are listed in the FAQ below.
Communication module (1746-BAS, 1747-KE, 1747-UIC) to 1747-AIC isolated link coupler. The length is the part that matters: in a panel the run between the processor port and the device it serves is fixed by the enclosure layout, and a cable that is too short forces the hardware to move.
Rockwell prints the cable lengths in the replacement cables and connectors table of 1747-UM011, which is the source used here. A distributor listing that quotes a different length for the same catalog number is quoting a different item.
Programming and DH-485 cabling in an SLC 500 system is a short list: a processor-to-peripheral cable, a processor-to-isolated-link-coupler cable, a communication-module-to-coupler cable, and the RS-232 programmer cable for channel 0 on the 5/03 and later.
This catalog number is one of those four roles. Getting the role wrong is the usual wiring fault: a cable that reaches the right connector but carries the wrong pinout will either not communicate or will communicate intermittently.
The RS-232 programmer cable carries two 9-pin DTE connectors and is wired for the SLC channel 0 port. The DH-485 cables carry the connector that matches the isolated link coupler and the processor or module port they serve.
Cables are wear items at a programming port that is used every shift. Keep one spare of the cable actually in use; a replacement with a different length or connector will not substitute in the same panel.
Check the connector types at both ends against the ports in the panel, check the printed length on the cable jacket, and check continuity pin by pin before the cable goes into service. A cable that has been coiled tight in a drawer for a decade can look perfect and fail on one conductor.
Rockwell's replacement category for this catalog number is No planned RA replacement.
Discontinued 2024-09-30. Cable catalog numbers in the 1747 family were withdrawn in several waves between 2013 and 2024; this one left the catalogue on that date.
For a plant that still runs SLC 500, the cable is a stock item rather than a project item: buy tested spares while they are available, because the pinouts are specific to this platform.
How long is 1747-C13?
914.4 mm (36 in).
What does 1747-C13 connect?
Communication module (1746-BAS, 1747-KE, 1747-UIC) to 1747-AIC isolated link coupler.
Is 1747-C13 still available from Rockwell?
No. Discontinued 2024-09-30, replacement category No planned RA replacement.
Can another cable be substituted?
Only with the same connector types and pinout. Length alone is not the specification.
What temperature range is published for 1747-C13?
0…60 °C (32…140 °F).
1747-C13 is a specialty module to isolated link coupler cable in the SLC 500 range. The SLC 500 modular system is a 1746 chassis with a separate power supply, a processor or I/O adapter in the left-most slot, and I/O modules in the remaining slots, and this part belongs to the processor side of that system rather than to the I/O side.
| Attribute | Value |
| Catalog number | 1747-C13 |
| Product type | specialty module to isolated link coupler cable |
| Function | Connects a BASIC or KE module to the 1747-AIC isolated link coupler |
| Also used for | Connecting the 1747-UIC RS-485 port to an AIC or to the SLC RJ45 port |
| Related cable | 1747-C11 for the processor-to-AIC link |
| Related cable | 1747-CP3 for processor RS-232 channel 0 to a PC |
The values above are the ones the SLC 500 selection guide publishes for this part, and they are the numbers that decide where it fits: a current draw enters the chassis budget, a memory size decides the program, and a cable length decides whether the link reaches the next cabinet.
Every processor in this range is a single-slot module that must sit in the left-most slot of a 1746 chassis, and the chassis power supply is a separate unit mounted on the left end rather than part of the processor. That is the structural reason a SLC 500 quote is never one part number: chassis, supply, processor and I/O are four separate lines, and the interconnect cable is a fifth.
A battery in this range is a scheduled part, not a fault part: the published backup is about five years for the 1747-L511 and about two years for the L514 and the later processors, with a battery LED on the processor as the only warning. A plant that replaces processors on failure rather than on battery life is replacing hardware that a battery would have saved.
Digital I/O capacity is published per processor family rather than per model: 7880 points for the SLC 5/01 and 8192 points for the later processors, with a ceiling of three local chassis and thirty slots. Those two ceilings are what decide whether a machine fits in one rack or needs a remote drop, and they apply before any I/O module is selected.
The DH-485 physical layer has its own rules that the bill of materials has to respect: one 1747-AIC isolated link coupler is required for each processor on the link when two or more processors share it, and a coupler is required at each end when any device sits more than 6.09 m (20 ft) from the processor. A link built without couplers works on a bench and fails in a panel.
Before ordering, confirm the processor memory and its 5V and 24V draws, confirm the cable against the length and the link it serves, and confirm that the chassis, supply and interconnect cable appear as separate lines on the same bill of materials.
Related models, options and spare parts for this range are listed in the Allen-Bradley SLC 500 1747 processors and chassis category.