Product Details:
Payment & Shipping Terms:
|
1747-C11 is a SLC Replacement Cable, 304.8 mm (12 in) long, used for: Processor to 1747-AIC isolated link coupler.
Rockwell discontinued the catalog number on 2018-08-31, replacement category Direct Replacement.
| 1747-C10 | SLC Replacement Cable 1.8 m (6 ft) | IN STOCK |
| 1747-C11 | SLC Replacement Cable 304.8 mm (12 in) | IN STOCK |
| 1747-C13 | SLC Cable 914.4 mm (36 in) | IN STOCK |
| 1747-C20 | SLC Replacement Cable 6.09 m (20 ft) | IN STOCK |
| 1747-CP3 | SLC 5/03 Programmer RS-232 Cable 3.96 m (12 ft), two 9-pin DTE connectors | IN STOCK |
Catalog number |
1747-C11 |
Description |
SLC Replacement Cable |
Length |
304.8 mm (12 in) |
Used for |
Processor to 1747-AIC isolated link coupler |
Operating temperature |
0…60 °C (32…140 °F) |
Discontinued date |
2018-08-31 |
Replacement category |
Direct Replacement |
Replacement product |
1747-C10 |
Publication |
1747-UM011 |
1747-C11 (SLC 500 programming / network cable, 304.8 mm (12 in)): it links the processor to the 1747-AIC isolated link coupler when the processor is to sit on a DH-485 network.
When to choose it: It is deliberately short: the AIC is mounted in the same enclosure as the CPU, so 12 in is the correct length and leaves the network side of the AIC free for the trunk. Using 1747-C13 here instead puts 36 in of cable inside the panel for no reason. A wrong cable in this position looks like a dead port rather than a wrong cable, so match the catalogue number to the port first. Source: Rockwell publication 1747-UM011, replacement cables and connectors section.
Attribute values above are reproduced from the manufacturer's product data. For the authoritative technical record see Rockwell publications 1747-UM011 (module specifications) and 1747-UM011 (installation instructions). Certification details, with certificate and file numbers, are listed in the FAQ below.
Processor to 1747-AIC isolated link coupler. The length is the part that matters: in a panel the run between the processor port and the device it serves is fixed by the enclosure layout, and a cable that is too short forces the hardware to move.
Rockwell prints the cable lengths in the replacement cables and connectors table of 1747-UM011, which is the source used here. A distributor listing that quotes a different length for the same catalog number is quoting a different item.
Programming and DH-485 cabling in an SLC 500 system is a short list: a processor-to-peripheral cable, a processor-to-isolated-link-coupler cable, a communication-module-to-coupler cable, and the RS-232 programmer cable for channel 0 on the 5/03 and later.
This catalog number is one of those four roles. Getting the role wrong is the usual wiring fault: a cable that reaches the right connector but carries the wrong pinout will either not communicate or will communicate intermittently.
The RS-232 programmer cable carries two 9-pin DTE connectors and is wired for the SLC channel 0 port. The DH-485 cables carry the connector that matches the isolated link coupler and the processor or module port they serve.
Cables are wear items at a programming port that is used every shift. Keep one spare of the cable actually in use; a replacement with a different length or connector will not substitute in the same panel.
Check the connector types at both ends against the ports in the panel, check the printed length on the cable jacket, and check continuity pin by pin before the cable goes into service. A cable that has been coiled tight in a drawer for a decade can look perfect and fail on one conductor.
Rockwell's replacement category for this catalog number is Direct Replacement, with 1747-C10 named as the replacement product.
Discontinued 2018-08-31. Cable catalog numbers in the 1747 family were withdrawn in several waves between 2013 and 2024; this one left the catalogue on that date.
For a plant that still runs SLC 500, the cable is a stock item rather than a project item: buy tested spares while they are available, because the pinouts are specific to this platform.
How long is 1747-C11?
304.8 mm (12 in).
What does 1747-C11 connect?
Processor to 1747-AIC isolated link coupler.
Is 1747-C11 still available from Rockwell?
No. Discontinued 2018-08-31, replacement category Direct Replacement, replacement product 1747-C10.
Can another cable be substituted?
Only with the same connector types and pinout. Length alone is not the specification.
What temperature range is published for 1747-C11?
0…60 °C (32…140 °F).
1747-C11 is a processor to isolated link coupler replacement cable in the SLC 500 range. The SLC 500 modular system is a 1746 chassis with a separate power supply, a processor or I/O adapter in the left-most slot, and I/O modules in the remaining slots, and this part belongs to the processor side of that system rather than to the I/O side.
| Attribute | Value |
| Catalog number | 1747-C11 |
| Product type | processor to isolated link coupler replacement cable |
| Length | 304.8 mm (12 in.) |
| Function | Connects the SLC 500 processor to the 1747-AIC isolated link coupler |
| Included with | 1747-AIC ships with a 1747-C11 |
| Use | Replacement cable, not a general purpose DH-485 lead |
The values above are the ones the SLC 500 selection guide publishes for this part, and they are the numbers that decide where it fits: a current draw enters the chassis budget, a memory size decides the program, and a cable length decides whether the link reaches the next cabinet.
Digital I/O capacity is published per processor family rather than per model: 7880 points for the SLC 5/01 and 8192 points for the later processors, with a ceiling of three local chassis and thirty slots. Those two ceilings are what decide whether a machine fits in one rack or needs a remote drop, and they apply before any I/O module is selected.
The cables in this range are specified by the link they serve rather than by the connector they present: 1747-CP3 is a 3 m 9-pin DTE lead for processor channel 0 to a PC, 1747-C11 is a 304.8 mm processor-to-AIC lead, and 1747-C13 is the specialty-module-to-AIC lead that also serves the 1747-UIC RS-485 port. Three cables that look interchangeable at the connector and are not interchangeable in use.
The DH-485 physical layer has its own rules that the bill of materials has to respect: one 1747-AIC isolated link coupler is required for each processor on the link when two or more processors share it, and a coupler is required at each end when any device sits more than 6.09 m (20 ft) from the processor. A link built without couplers works on a bench and fails in a panel.
Memory and backplane current move together across the processor ladder: the 1747-L511 carries 1 K words and draws 90 mA at 5V with nothing at 24V, the L514 carries 4 K words and draws 500 mA at 5V plus 175 mA at 24V, and the L524 carries 4 K words and draws 1000 mA at 5V plus 200 mA at 24V. Choosing a processor by memory and then discovering its 24V draw has eaten the analog budget is the usual sequencing error.
Before ordering, confirm the processor memory and its 5V and 24V draws, confirm the cable against the length and the link it serves, and confirm that the chassis, supply and interconnect cable appear as separate lines on the same bill of materials.
The Allen-Bradley SLC 500 1747 processors and chassis category lists the related catalog numbers, options and accessories for this range.