|
Product Details:
Payment & Shipping Terms:
|
1747-AIC is the SLC Isolated Link Coupler.
Isolates and couples nodes onto a DH-485 link. SLC 5/01 and 5/02 processors reach the link through 1747-C10/C11, communication modules through 1747-C13. Rockwell lists the catalog number as discontinued on 2017-01-31, replacement category Engineering Replacement.
| 1747-SN | SLC Remote I/O Scanner Module | IN STOCK |
| 1747-SCNR | SLC ControlNet Scanner | IN STOCK |
| 1747-SDN | SLC DeviceNet Scanner Module | IN STOCK |
| 1747-ASB | SLC Remote I/O Adapter Module | IN STOCK |
| 1747-BSN | SLC Backup Scanner Module | IN STOCK |
| 1747-ACN15 | SLC ControlNet Adapter Module | IN STOCK |
| 1747-ACNR15 | SLC ControlNet Adapter Module, redundant media | IN STOCK |
| 1747-DCM | SLC Direct Communication Module | IN STOCK |
| 1747-KE | Communication Interface Module, DH-485 to RS-232C | IN STOCK |
| 1747-KFC15 | SLC Interface Module | IN STOCK |
| 1747-UIC | SLC USB to DH-485 Converter | IN STOCK |
| 1747-UICC13 | USB Converter Cable | IN STOCK |
| 1747-PIC | SLC RS-232 to DH-485 Interface Converter | IN STOCK |
| 1747-AIC | SLC Isolated Link Coupler | IN STOCK |
| 1747-DPS1 | SLC Data Port Splitter | IN STOCK |
| 1747-DPS2 | SLC Data Port Splitter | IN STOCK |
Catalog number |
1747-AIC |
Description |
SLC Isolated Link Coupler |
Module type |
Isolated link coupler |
Channels |
DH-485 link coupling |
Isolation |
500V dc on communication circuits |
Rockwell class |
Coupler |
Discontinued date |
2017-01-31 |
Replacement category |
Engineering Replacement |
Replacement product |
None published |
Publication |
1747-UM011 / 1747-IN009 |
Attribute values above are reproduced from the manufacturer's product data. For the authoritative technical record see Rockwell publications 1747-IN062 (module specifications) and 1747-IN062 (installation instructions). Certification details, with certificate and file numbers, are listed in the FAQ below.
Isolates and couples nodes onto a DH-485 link. SLC 5/01 and 5/02 processors reach the link through 1747-C10/C11, communication modules through 1747-C13.
It is a single-slot module for a 1746 chassis, powered from the rack backplane. Nothing in the chassis changes when it is fitted: the processor still occupies slot 0 of the first rack, and the module sits in any other slot.
Rockwell prints DH-485 link coupling for this catalog number, and isolation of 500V dc on communication circuits.
Isolation matters at the point where the network meets the panel: a communication port that is not isolated couples network transients into the backplane, and the usual symptom is a module that resets when a drive on the same network switches.
SLC 500 systems reach other devices over four routes: DH-485 for peer-to-peer and programming, DH+ for PLC-5 class networks, Remote I/O for scanner and adapter racks, and the fieldbus scanners for DeviceNet and ControlNet. Each route has a distinct module pair, and mixing them up is the commonest commissioning error.
This catalog number belongs to one of those routes. The module on the other side of the link has to match it: a scanner needs an adapter, and an adapter needs a scanner. Two adapters on the same link do nothing.
Set the node address and the baud rate before the module goes into the rack, record both on the panel schedule, and confirm the processor sees the module in its I/O configuration. A module that is fitted but not configured in the program behaves like a missing module, not like a fault.
On a working line, the safe sequence is: power down the rack, fit the module, power up with the processor in PROG, download the configuration, then switch to RUN and watch the module status for a full production cycle.
Rockwell discontinued this catalog number on 2017-01-31 with replacement category Engineering Replacement.
Communication modules are the parts that fail first in an SLC 500 panel, because they carry the surge path. Keep a tested spare of the exact catalog number, and record the firmware or series letter of the working module next to it.
What is 1747-AIC?
SLC Isolated Link Coupler Isolates and couples nodes onto a DH-485 link. SLC 5/01 and 5/02 processors reach the link through 1747-C10/C11, communication modules through 1747-C13.
How many channels does 1747-AIC have?
Rockwell prints DH-485 link coupling for this catalog number.
Is 1747-AIC still available from Rockwell?
No. Discontinued 2017-01-31, replacement category Engineering Replacement.
What is the isolation rating?
500V dc on communication circuits.
Does 1747-AIC need a matching module at the other end of the link?
Yes. A scanner needs an adapter and an adapter needs a scanner on the same link.
Eight catalog numbers sit between a computer or a DF1 device and the DH-485 link, and they are not alternatives to each other: one converts RS-232, one converts USB, one isolates the link, one bridges DF1, and two split a processor port. Reading the channel column is how the right one gets chosen.
| Catalog | What it is | Channel printed | Isolation printed | Lifecycle |
| 1747-KE | DH-485 to RS-232C interface | One DH-485 port and one RS-232C port | Not published | 2013-12-01, No planned RA replacement |
| 1747-KFC15 | Interface module | Not published | Not published | 2014-01-05, No planned RA replacement |
| 1747-PIC | RS-232 to DH-485 converter | RS-232 port and DH-485 port | Not published | 2015-12-31, Engineering Replacement |
| 1747-UIC | USB to DH-485 converter | USB port and DH-485 port | Not published | 2024-09-30, No planned RA replacement |
| 1747-UICC13 | Interface cable for 1747-UIC | Not published | Not published | Not published, Not published |
| 1747-AIC | Isolated link coupler | DH-485 link coupling | 500V dc on communication circuits | 2017-01-31, Engineering Replacement |
| 1747-DPS1 | Port splitter | Not published | Not published | Not published, Not published |
| 1747-DPS2 | Port splitter | Not published | Not published | Not published, Not published |
Where this converter sits: 1747-AIC sits at the isolation point on a DH-485 link. The printed port line is "DH-485 link coupling", the printed isolation is 500V dc on communication circuits. Lifecycle: 2017-01-31, Engineering Replacement.
The port converters are the part of this family that is hardest to buy today: 2 of the eight on this list carry an engineering-replacement status and 7 publish no isolation figure, so a computer on a DH-485 link is usually built from a 1747-UIC plus the right cable rather than from the older converters. Cable pairing is printed per converter and is not interchangeable.
Source: Rockwell 1747-IN009, 1747-IN007, 1747-IN019, 1747-IN062, 1747-UM011 and 1747-RM001 as recorded per catalog number, plus the Rockwell product page for each number. Every figure is quoted as printed; no value is calculated.
The Allen-Bradley SLC 500 1747 processors and chassis category groups the other catalog numbers, options and spare parts in the same range.