Product Details:
Payment & Shipping Terms:
|
1747-ACN15 is the SLC ControlNet Adapter Module.
ControlNet adapter for a 1746 chassis. Rockwell's product page for this catalog number has been withdrawn, so no lifecycle date or isolation figure is printed here. Rockwell's product page for this catalog number has been withdrawn, so no lifecycle date is on record.
| 1747-SN | SLC Remote I/O Scanner Module | IN STOCK |
| 1747-SCNR | SLC ControlNet Scanner | IN STOCK |
| 1747-SDN | SLC DeviceNet Scanner Module | IN STOCK |
| 1747-ASB | SLC Remote I/O Adapter Module | IN STOCK |
| 1747-BSN | SLC Backup Scanner Module | IN STOCK |
| 1747-ACN15 | SLC ControlNet Adapter Module | IN STOCK |
| 1747-ACNR15 | SLC ControlNet Adapter Module, redundant media | IN STOCK |
| 1747-DCM | SLC Direct Communication Module | IN STOCK |
| 1747-KE | Communication Interface Module, DH-485 to RS-232C | IN STOCK |
| 1747-KFC15 | SLC Interface Module | IN STOCK |
| 1747-UIC | SLC USB to DH-485 Converter | IN STOCK |
| 1747-UICC13 | USB Converter Cable | IN STOCK |
| 1747-PIC | SLC RS-232 to DH-485 Interface Converter | IN STOCK |
| 1747-AIC | SLC Isolated Link Coupler | IN STOCK |
| 1747-DPS1 | SLC Data Port Splitter | IN STOCK |
| 1747-DPS2 | SLC Data Port Splitter | IN STOCK |
Catalog number |
1747-ACN15 |
Description |
SLC ControlNet Adapter Module |
Module type |
ControlNet adapter |
Channels |
ControlNet adapter channel |
Isolation |
Not published |
Rockwell class |
Communication adapter |
Discontinued date |
Not published |
Replacement category |
Not published |
Replacement product |
None published |
Publication |
1747-UM011 / 1747-IN009 |
Attribute values above are reproduced from the manufacturer's product data. For the authoritative technical record see Rockwell publications 1747-IN009 (module specifications) and 1747-IN009 (installation instructions). Certification details, with certificate and file numbers, are listed in the FAQ below.
ControlNet adapter for a 1746 chassis. Rockwell's product page for this catalog number has been withdrawn, so no lifecycle date or isolation figure is printed here.
It is a single-slot module for a 1746 chassis, powered from the rack backplane. Nothing in the chassis changes when it is fitted: the processor still occupies slot 0 of the first rack, and the module sits in any other slot.
Rockwell prints ControlNet adapter channel for this catalog number, and no isolation figure on the product page.
Because no isolation figure is printed for this catalog number, treat the port as unspecified and confirm with a Rockwell publication before designing a network where common-mode noise is expected.
SLC 500 systems reach other devices over four routes: DH-485 for peer-to-peer and programming, DH+ for PLC-5 class networks, Remote I/O for scanner and adapter racks, and the fieldbus scanners for DeviceNet and ControlNet. Each route has a distinct module pair, and mixing them up is the commonest commissioning error.
This catalog number belongs to one of those routes. The module on the other side of the link has to match it: a scanner needs an adapter, and an adapter needs a scanner. Two adapters on the same link do nothing.
Set the node address and the baud rate before the module goes into the rack, record both on the panel schedule, and confirm the processor sees the module in its I/O configuration. A module that is fitted but not configured in the program behaves like a missing module, not like a fault.
On a working line, the safe sequence is: power down the rack, fit the module, power up with the processor in PROG, download the configuration, then switch to RUN and watch the module status for a full production cycle.
Rockwell's product page for this catalog number has been withdrawn. No discontinued date and no replacement category are printed on record, so this page states neither.
Communication modules are the parts that fail first in an SLC 500 panel, because they carry the surge path. Keep a tested spare of the exact catalog number, and record the firmware or series letter of the working module next to it.
What is 1747-ACN15?
SLC ControlNet Adapter Module ControlNet adapter for a 1746 chassis. Rockwell's product page for this catalog number has been withdrawn, so no lifecycle date or isolation figure is printed here.
How many channels does 1747-ACN15 have?
Rockwell prints ControlNet adapter channel for this catalog number.
Is 1747-ACN15 still available from Rockwell?
The Rockwell product page has been withdrawn; no discontinued date is on record.
What is the isolation rating?
Not published.
Does 1747-ACN15 need a matching module at the other end of the link?
Yes. A scanner needs an adapter and an adapter needs a scanner on the same link.
Eight catalog numbers are the network side of the SLC family, and the useful split is not by protocol but by which end of the link they sit on: five are scanned or scan, and three answer. That is what decides whether a module goes in the processor chassis or in a remote one.
| Catalog | What it is | Channel printed | Isolation printed | Lifecycle |
| 1747-SN | Remote I/O scanner | 4 channels | 500V dc on communication circuits | 2024-03-31, Engineering Replacement |
| 1747-SCNR | ControlNet scanner | ControlNet scanner channel | Not published | 2015-12-31, Engineering Replacement |
| 1747-SDN | DeviceNet scanner, Series C | DeviceNet scanner channel | 500V dc on communication circuits | 2024-03-31, Engineering Replacement |
| 1747-ASB | Remote I/O adapter | Remote I/O adapter channel | Not published | 2013-11-01, No planned RA replacement |
| 1747-BSN | Backup scanner | Remote I/O scanner channel | Not published | 2015-12-31, Engineering Replacement |
| 1747-ACN15 | ControlNet adapter | ControlNet adapter channel | Not published | Not published, Not published |
| 1747-ACNR15 | ControlNet adapter, redundant media | Two ControlNet media ports | Not published | Not published, Not published |
| 1747-DCM | Communication module | Not published | Not published | Not published, Not published |
Where this module sits: 1747-ACN15 is the ControlNet adapter for a 1746 chassis, so it belongs on the answering side of a ControlNet link. The printed channel line is "ControlNet adapter channel" and the printed isolation is Not published; the lifecycle row reads Not published, Not published.
This map prints what each catalog number is and which side of a link it sits on. It does not print node counts, cable lengths or baud rates per module - those live in 1747-UM011 and in the scanner instruction sheets, and several of the withdrawn catalog numbers (1747-ACN15, 1747-DCM) publish no channel or isolation figure at all, so none is inferred for them.
Source: Rockwell 1747-IN009, 1747-IN007, 1747-IN019, 1747-IN062, 1747-UM011 and 1747-RM001 as recorded per catalog number, plus the Rockwell product page for each number. Every figure is quoted as printed; no value is calculated.
Other catalog numbers and accessories for the same range are collected in the Allen-Bradley SLC 500 1747 processors and chassis category.