logo
Home ProductsAB Drives & Motors

Allen Bradley PowerFlex 22F-D8P7N113 / 22FD8P7N113

Customer Reviews
Welcome to PLC-VIP , Your online shop for Allen Bradley & Siemens PLC parts.

—— PLC-VIP.SHOP

We also wish to be able to continue doing good business with you and your company in the years to come. We are very thankful for that.

—— Rodrigo

I'm Online Chat Now

Allen Bradley PowerFlex 22F-D8P7N113 / 22FD8P7N113

China Allen Bradley PowerFlex 22F-D8P7N113 / 22FD8P7N113 supplier
Allen Bradley PowerFlex 22F-D8P7N113 / 22FD8P7N113 supplier Allen Bradley PowerFlex 22F-D8P7N113 / 22FD8P7N113 supplier Allen Bradley PowerFlex 22F-D8P7N113 / 22FD8P7N113 supplier Allen Bradley PowerFlex 22F-D8P7N113 / 22FD8P7N113 supplier Allen Bradley PowerFlex 22F-D8P7N113 / 22FD8P7N113 supplier Allen Bradley PowerFlex 22F-D8P7N113 / 22FD8P7N113 supplier Allen Bradley PowerFlex 22F-D8P7N113 / 22FD8P7N113 supplier Allen Bradley PowerFlex 22F-D8P7N113 / 22FD8P7N113 supplier Allen Bradley PowerFlex 22F-D8P7N113 / 22FD8P7N113 supplier Allen Bradley PowerFlex 22F-D8P7N113 / 22FD8P7N113 supplier Allen Bradley PowerFlex 22F-D8P7N113 / 22FD8P7N113 supplier Allen Bradley PowerFlex 22F-D8P7N113 / 22FD8P7N113 supplier Allen Bradley PowerFlex 22F-D8P7N113 / 22FD8P7N113 supplier Allen Bradley PowerFlex 22F-D8P7N113 / 22FD8P7N113 supplier Allen Bradley PowerFlex 22F-D8P7N113 / 22FD8P7N113 supplier

Large Image :  Allen Bradley PowerFlex 22F-D8P7N113 / 22FD8P7N113

Product Details:

Place of Origin: Made in CHINA
Brand Name: PLC Module
Certification: All goods we supply are 100% original factory sealed with 1 year warranty!
Model Number: Allen Bradley PowerFlex 22F-D8P7N113 / 22FD8P7N113

Payment & Shipping Terms:

Minimum Order Quantity: 1 /PCS
Price: $315.00 (USD/PCS)
Packaging Details: 100% original new
Delivery Time: IN STOCK; 4-6 weeks for ordering
Payment Terms: T/T, Western Union and Paypal.
Supply Ability: 5 PCS
Detailed Product Description

22F-D8P7N113

This page documents the 22F-D8P7N113, a PowerFlex 4M (bulletin 22F) drive in the 480 V three-phase class: 3.7 kW (5.0 HP), 8.7 A continuous output, frame B, IP20 panel mount, with integral EMC filter. The rating, the frame, the terminal sizes, the protection rows and the cable allowances are quoted from the PowerFlex 4M user manual 22F-UM001.

Catalog number decode

FieldValue
Catalog number22F-D8P7N113
Family22F - PowerFlex 4M, adjustable frequency AC drive, IP20 panel mount only
Voltage code (character 5)D - 480 V three-phase
Rating code (characters 6-8)8P7 - 3.7 kW (5.0 HP), 8.7 A continuous
FrameB
Enclosure (character 9)N - IP20, the only enclosure form this family publishes
HIM position (character 10)1
Emission class (character 11)1 - with integral EMC filter
Type (character 12)3 - carried, resolved in the option appendix rather than here
Positions 13-14not used on this string

Published rating row

AttributeValue
Output current8.7 A continuous
Motor rating3.7 kW (5.0 HP)
Input window340-528 V
FrameB
Terminal block8.4 mm2 (8 AWG) maximum, 0.8 mm2 (18 AWG) minimum, 1.6-1.9 N.m (14-17 lb-in)
Input kVApublished in the ratings table for this row
Input currentpublished in the ratings table for this row
Fuse, 40 C NECpublished in the ratings table for this row
140M / 140MT controllerpublished per rating in the protection table
Contactorpublished per rating in the protection table
Minimum enclosure volumepublished in the ratings table for this row

Frame B sets the terminal block to 8.4 mm2 (8 AWG) maximum and 0.8 mm2 (18 AWG) minimum at 1.6-1.9 N.m (14-17 lb-in). Those are the sizes the block accepts, not a recommendation for the motor lead, and the minimum is what decides whether a small motor cable can be landed directly or has to go through a junction.

Branch protection is outside the drive

The 4M does not provide branch short-circuit protection. It has to be installed with input fuses or an input circuit breaker, and national and local codes can add requirements on top of that. The manual states the point twice and adds an attention note about using only the recommended line fuses or breakers, because an improvised device voids the basis on which the drive was tested. This page covers 22F-D8P7N113 and its ordering options.

The fuse amperage, the controller, the contactor and the enclosure volume for this rating are printed in the drive ratings table of 22F-UM001 and are not reproduced here, because a figure copied from a neighbouring rating would be a guess. What the publication does fix for every code is the requirement: input fuses or a circuit breaker, 140M/140MT controllers accepted upstream without fuses, and a UL-tested fuse basis.

Emission character and the motor cable it allows

Character 11 reads 1, so this drive ships with integral EMC filter. The character does not change the rating, the frame or the terminal block; it changes the EMC environment the drive may be installed in and the motor cable length the manual permits.

Because the filter is inside the drive, the panel does not carry a separate filter enclosure, no external filter wiring is added between the drive and the motor, and the allowance that applies is the integral one: 5 m in the second environment on a 240 V drive, 10 m on a 480 V drive, and 1 m in the first environment where distribution is unrestricted. The 8.7 A rating and frame B are unaffected by the character, so the mechanical layout is the same as an unfiltered string of the same rating.

Filter routeSecond environmentFirst environment, unrestricted distribution
Integral filter, 240 V drive5 m1 m
Integral filter, 480 V drive10 msee the same table in 22F-UM001
External S-type filter5 m1 m
External L-type filter100 m25 m

An unfiltered drive on a long motor lead is a drive that fails an emissions check later, and the correction at that point is an external filter plus a retest rather than a catalog change. That is the practical reason a filtered code is ordered even where no regulation is quoted at the quotation stage. The catalog number covered on this page is 22F-D8P7N113.

Software limits that replace a larger catalog number

Output current is limited in software rather than by the frame. The current-limit parameter defaults to 1.5 times the drive rated amps and can be raised to 1.8 times, and the output-current monitor reads up to twice the rated amps. A drive one frame larger than the motor is therefore made safe for that motor by a parameter setting, and a machine that needs a slower ramp needs a different parameter rather than a different drive..

Same rating, other strings

The same rating and voltage class appear under other strings: 22F-D8P7N103. They differ in the enclosure, interface or emission characters rather than in the power section, so the choice between them is made on the panel and the cable route, not on the current.

Filter class decides the motor lead. The emission character does not change the rating, the frame or the terminals; it changes the environment the drive may be installed in and the motor cable length the manual allows. An integral 240 V filter is good for 5 m in the second environment, an integral 480 V filter for 10 m, an external S-type filter for 5 m, and an external L-type filter for 100 m outside the unrestricted first environment.

Frame letters and the wire that fits. Frames A, B and C set both the terminal block and the panel footprint: 12 AWG maximum on frame A, 8 AWG on frame B, 6 AWG on frame C. The minimum sizes matter as much as the maximum, because a small motor cable below the block minimum has to be landed through a junction rather than directly.

Protection device classes. The fuses are constrained by class as well as by current: BS88 parts 1 and 2 or EN60269-1 type gG for IEC installations, Class CC, T or J for UL. A fuse of the right amperage in the wrong class is not a substitute, and the manual states the acceptable classes in the same table as the size.

A 140m controller upstream without fuses. Bulletin 140M and 140MT self-protected controllers are accepted upstream of the drive without fuses. That route is what saves panel width when a motor-protective controller is already in the design, and it is the difference between a panel that repeats protection twice and one that does not.

Current limit as a substitute for a different drive. Output current is limited in software: the current-limit parameter defaults to 1.5 times the drive rated amps and can be raised to 1.8 times, while the output-current monitor reads to twice the rated amps. A drive one frame larger than the motor is therefore made safe for that motor by a parameter, not by a second catalog number.

Panel thermal and mounting. Estimated watts loss is published per rating at rated load, rated speed and rated PWM, and it is a drive-only figure used in the panel thermal calculation. Panel mounting is the only form this family publishes, with a 1.9 mm minimum panel thickness and M4 screws at 1.56...1.96 N.m..

The 4M is the small-machine drive in this family, and the tell is in the protection table: it is the drive that does not carry branch short-circuit protection internally, so the panel around it has to supply it.

No price, lead time or lifecycle statement is implied. The rating, frame, terminal, protection and cable-length figures above are quoted from the PowerFlex 4M user manual, publication 22F-UM001, for this catalog number..

Related catalog numbers in the 22F range

Twelve of the 34 22F records carried on this site, ordered by how close their codes sit to this one. This page is 22F-D8P7N113.

This listing is filed in the AB Drives & Motors group on plc-vip.com; the group index is AB Drives & Motors catalogue index, and the 22F-D8P7N113 page is one entry in it. Sibling codes of the same group are one click away from that page.

Contact Details
PLC-VIP SHOP

Contact Person: Miss. linda

Tel: 00-852-65626925

Fax: 00-852-90164956

Send your inquiry directly to us (0 / 3000)