logo
Home ProductsAB Drives & Motors

Allen Bradley PowerFlex 22F-D1P5N103 / 22FD1P5N103

Customer Reviews
Welcome to PLC-VIP , Your online shop for Allen Bradley & Siemens PLC parts.

—— PLC-VIP.SHOP

We also wish to be able to continue doing good business with you and your company in the years to come. We are very thankful for that.

—— Rodrigo

I'm Online Chat Now

Allen Bradley PowerFlex 22F-D1P5N103 / 22FD1P5N103

China Allen Bradley PowerFlex 22F-D1P5N103 / 22FD1P5N103 supplier
Allen Bradley PowerFlex 22F-D1P5N103 / 22FD1P5N103 supplier Allen Bradley PowerFlex 22F-D1P5N103 / 22FD1P5N103 supplier Allen Bradley PowerFlex 22F-D1P5N103 / 22FD1P5N103 supplier Allen Bradley PowerFlex 22F-D1P5N103 / 22FD1P5N103 supplier Allen Bradley PowerFlex 22F-D1P5N103 / 22FD1P5N103 supplier Allen Bradley PowerFlex 22F-D1P5N103 / 22FD1P5N103 supplier Allen Bradley PowerFlex 22F-D1P5N103 / 22FD1P5N103 supplier Allen Bradley PowerFlex 22F-D1P5N103 / 22FD1P5N103 supplier Allen Bradley PowerFlex 22F-D1P5N103 / 22FD1P5N103 supplier Allen Bradley PowerFlex 22F-D1P5N103 / 22FD1P5N103 supplier Allen Bradley PowerFlex 22F-D1P5N103 / 22FD1P5N103 supplier Allen Bradley PowerFlex 22F-D1P5N103 / 22FD1P5N103 supplier Allen Bradley PowerFlex 22F-D1P5N103 / 22FD1P5N103 supplier Allen Bradley PowerFlex 22F-D1P5N103 / 22FD1P5N103 supplier Allen Bradley PowerFlex 22F-D1P5N103 / 22FD1P5N103 supplier

Large Image :  Allen Bradley PowerFlex 22F-D1P5N103 / 22FD1P5N103

Product Details:

Place of Origin: Made in CHINA
Brand Name: PLC Module
Certification: All goods we supply are 100% original factory sealed with 1 year warranty!
Model Number: Allen Bradley PowerFlex 22F-D1P5N103 / 22FD1P5N103

Payment & Shipping Terms:

Minimum Order Quantity: 1 /PCS
Price: $150.00 (USD/PCS)
Packaging Details: 100% original new
Delivery Time: IN STOCK; 4-6 weeks for ordering
Payment Terms: T/T, Western Union and Paypal.
Supply Ability: 5 PCS
Detailed Product Description

22F-D1P5N103

This page documents the 22F-D1P5N103, a PowerFlex 4M (bulletin 22F) drive in the 480 V three-phase class: 0.4 kW (0.5 HP), 1.5 A continuous output, frame A, IP20 panel mount, without integral EMC filter. The rating, the frame, the terminal sizes, the protection rows and the cable allowances are quoted from the PowerFlex 4M user manual 22F-UM001.

Catalog number decode

FieldValue
Catalog number22F-D1P5N103
Family22F - PowerFlex 4M, adjustable frequency AC drive, IP20 panel mount only
Voltage code (character 5)D - 480 V three-phase
Rating code (characters 6-8)1P5 - 0.4 kW (0.5 HP), 1.5 A continuous
FrameA
Enclosure (character 9)N - IP20, the only enclosure form this family publishes
HIM position (character 10)1
Emission class (character 11)0 - without integral EMC filter
Type (character 12)3 - carried, resolved in the option appendix rather than here
Positions 13-14not used on this string

Published rating row

AttributeValue
Output current1.5 A continuous
Motor rating0.4 kW (0.5 HP)
Input window340-528 V
FrameA
Terminal block3.3 mm2 (12 AWG) maximum, 0.8 mm2 (18 AWG) minimum, 1.4-1.6 N.m (12-14 lb-in)
Input kVApublished in the ratings table for this row
Input currentpublished in the ratings table for this row
Fuse, 40 C NECpublished in the ratings table for this row
140M / 140MT controllerpublished per rating in the protection table
Contactorpublished per rating in the protection table
Minimum enclosure volumepublished in the ratings table for this row

Frame A sets the terminal block to 3.3 mm2 (12 AWG) maximum and 0.8 mm2 (18 AWG) minimum at 1.4-1.6 N.m (12-14 lb-in). Those are the sizes the block accepts, not a recommendation for the motor lead, and the minimum is what decides whether a small motor cable can be landed directly or has to go through a junction.

Branch protection is outside the drive

The 4M does not provide branch short-circuit protection. It has to be installed with input fuses or an input circuit breaker, and national and local codes can add requirements on top of that. The manual states the point twice and adds an attention note about using only the recommended line fuses or breakers, because an improvised device voids the basis on which the drive was tested. This page covers 22F-D1P5N103 and its ordering options.

The fuse amperage, the controller, the contactor and the enclosure volume for this rating are printed in the drive ratings table of 22F-UM001 and are not reproduced here, because a figure copied from a neighbouring rating would be a guess. What the publication does fix for every code is the requirement: input fuses or a circuit breaker, 140M/140MT controllers accepted upstream without fuses, and a UL-tested fuse basis.

Emission character and the motor cable it allows

Character 11 reads 0, so this drive ships without integral EMC filter. The character does not change the rating, the frame or the terminal block; it changes the EMC environment the drive may be installed in and the motor cable length the manual permits.

Because no filter is inside the drive, an installation in a regulated environment needs an external unit in the panel: an S-type filter for a short lead or an L-type filter for a long one, with the allowances published for each. The 1.5 A rating and frame A are the same as the filtered string of the same rating; what changes is the cable length that can be certified, so a site survey that measures the motor lead comes before the order, not after it.

Filter routeSecond environmentFirst environment, unrestricted distribution
Integral filter, 240 V drive5 m1 m
Integral filter, 480 V drive10 msee the same table in 22F-UM001
External S-type filter5 m1 m
External L-type filter100 m25 m

An unfiltered drive on a long motor lead is a drive that fails an emissions check later, and the correction at that point is an external filter plus a retest rather than a catalog change. That is the practical reason a filtered code is ordered even where no regulation is quoted at the quotation stage. This entry is for 22F-D1P5N103.

Software limits that replace a larger catalog number

Output current is limited in software rather than by the frame. The current-limit parameter defaults to 1.5 times the drive rated amps and can be raised to 1.8 times, and the output-current monitor reads up to twice the rated amps. A drive one frame larger than the motor is therefore made safe for that motor by a parameter setting, and a machine that needs a slower ramp needs a different parameter rather than a different drive. This page covers 22F-D1Pily:arial,helvetica,sans-serif;font-size:14px;color:#000000;">Same rating, other strings

The same rating and voltage class appear under other strings: 22F-D1P5N113. They differ in the enclosure, interface or emission characters rather than in the power section, so the choice between them is made on the panel and the cable route, not on the current.

What the parameter number means over modbus. Over Modbus the register address equals the parameter number, so decimal 1 addresses d001 output frequency and decimal 109 addresses P109 acceleration time 1. A controls engineer commissioning from a PLC needs the parameter list rather than the catalog string, and the string is the part that has to be right before that work starts.

The panel mounting thickness. Panel mounting is the only mechanical form this family publishes, with a 1.9 mm (0.0747 in) minimum panel thickness and M4 (#8-32) screws at 1.56...1.96 N.m. That is thinner than the larger drive families expect, and it is the figure that decides whether the drive can sit on a machine frame instead of in a cabinet.

Reorder risk on the emission character. Two drives with the same rating and different character 11 are different products when the cable run is long. A spare ordered by rating alone can arrive unfiltered into an installation that was commissioned with a filter, and the mismatch shows up as an emission problem rather than as a wrong part number.

The two things a 4m does not contain. The 4M carries no branch short-circuit protection and no integral EMC filter on the unfiltered codes. Both have to be supplied around it: fuses or a circuit breaker upstream, and either the integral filter option or an external filter where the installation is regulated. A panel drawn around a bare 4M is a panel whose protection and emission compliance live in other line items.

Single-phase input, three-phase output. A 240 V single-phase 4M produces three-phase output from a single-phase supply, which is why small conveyors and fans in light-duty panels can use it at all. The motor is still a three-phase motor, and the input and output phase counts are two separate questions on this family.

Panel thermal and mounting. Estimated watts loss is published per rating at rated load, rated speed and rated PWM, and it is a drive-only figure used in the panel thermal calculation. Panel mounting is the only form this family publishes, with a 1.9 mm minimum panel thickness and M4 screws at 1.56...1.96 N.m. This page covers 22F-D1Ply:arial,helvetica,sans-serif;font-size:14px;color:#000000;">The 4M is the small-machine drive in this family, and the tell is in the protection table: it is the drive that does not carry branch short-circuit protection internally, so the panel around it has to supply it.

No price, lead time or lifecycle statement is implied. The rating, frame, terminal, protection and cable-length figures above are quoted from the PowerFlex 4M user manual, publication 22F-UM001, for this catalog number. This page covers 22F-D1Pcmp>

Related catalog numbers in the 22F range

Twelve of the 34 22F records carried on this site, ordered by how close their codes sit to this one. This page is 22F-D1P5N103.

This listing is filed in the AB Drives & Motors group on plc-vip.com; the group index is AB Drives & Motors catalogue index, and the 22F-D1P5N103 page is one entry in it. The index sits one level above this page in the site tree.

Contact Details
PLC-VIP SHOP

Contact Person: Miss. linda

Tel: 00-852-65626925

Fax: 00-852-90164956

Send your inquiry directly to us (0 / 3000)