logo
Home ProductsAB Drives & Motors

Allen Bradley PowerFlex 22F-B8P0N103 / 22FB8P0N103

Customer Reviews
Welcome to PLC-VIP , Your online shop for Allen Bradley & Siemens PLC parts.

—— PLC-VIP.SHOP

We also wish to be able to continue doing good business with you and your company in the years to come. We are very thankful for that.

—— Rodrigo

I'm Online Chat Now

Allen Bradley PowerFlex 22F-B8P0N103 / 22FB8P0N103

China Allen Bradley PowerFlex 22F-B8P0N103 / 22FB8P0N103 supplier
Allen Bradley PowerFlex 22F-B8P0N103 / 22FB8P0N103 supplier Allen Bradley PowerFlex 22F-B8P0N103 / 22FB8P0N103 supplier Allen Bradley PowerFlex 22F-B8P0N103 / 22FB8P0N103 supplier Allen Bradley PowerFlex 22F-B8P0N103 / 22FB8P0N103 supplier Allen Bradley PowerFlex 22F-B8P0N103 / 22FB8P0N103 supplier Allen Bradley PowerFlex 22F-B8P0N103 / 22FB8P0N103 supplier Allen Bradley PowerFlex 22F-B8P0N103 / 22FB8P0N103 supplier Allen Bradley PowerFlex 22F-B8P0N103 / 22FB8P0N103 supplier Allen Bradley PowerFlex 22F-B8P0N103 / 22FB8P0N103 supplier Allen Bradley PowerFlex 22F-B8P0N103 / 22FB8P0N103 supplier Allen Bradley PowerFlex 22F-B8P0N103 / 22FB8P0N103 supplier Allen Bradley PowerFlex 22F-B8P0N103 / 22FB8P0N103 supplier Allen Bradley PowerFlex 22F-B8P0N103 / 22FB8P0N103 supplier Allen Bradley PowerFlex 22F-B8P0N103 / 22FB8P0N103 supplier Allen Bradley PowerFlex 22F-B8P0N103 / 22FB8P0N103 supplier

Large Image :  Allen Bradley PowerFlex 22F-B8P0N103 / 22FB8P0N103

Product Details:

Place of Origin: Made in CHINA
Brand Name: PLC Module
Certification: All goods we supply are 100% original factory sealed with 1 year warranty!
Model Number: Allen Bradley PowerFlex 22F-B8P0N103 / 22FB8P0N103

Payment & Shipping Terms:

Minimum Order Quantity: 1 /PCS
Price: $169.00 (USD/PCS)
Packaging Details: 100% original new
Delivery Time: IN STOCK; 4-6 weeks for ordering
Payment Terms: T/T, Western Union and Paypal.
Supply Ability: 5 PCS
Detailed Product Description

22F-B8P0N103

This page documents the 22F-B8P0N103, a PowerFlex 4M (bulletin 22F) drive in the 240 V three-phase class: 1.5 kW (2.0 HP), 8.0 A continuous output, frame A, IP20 panel mount, without integral EMC filter. The rating, the frame, the terminal sizes, the protection rows and the cable allowances are quoted from the PowerFlex 4M user manual 22F-UM001.

Catalog number decode

FieldValue
Catalog number22F-B8P0N103
Family22F - PowerFlex 4M, adjustable frequency AC drive, IP20 panel mount only
Voltage code (character 5)B - 240 V three-phase
Rating code (characters 6-8)8P0 - 1.5 kW (2.0 HP), 8.0 A continuous
FrameA
Enclosure (character 9)N - IP20, the only enclosure form this family publishes
HIM position (character 10)1
Emission class (character 11)0 - without integral EMC filter
Type (character 12)3 - carried, resolved in the option appendix rather than here
Positions 13-14not used on this string

Published rating row

AttributeValue
Output current8.0 A continuous
Motor rating1.5 kW (2.0 HP)
Input window180-265 V
FrameA
Terminal block3.3 mm2 (12 AWG) maximum, 0.8 mm2 (18 AWG) minimum, 1.4-1.6 N.m (12-14 lb-in)
Input kVA4.0
Input current9.5 A
Fuse, 40 C NEC15 A
140M / 140MT controller140M-C2E-C16 or 140MT-C3E-C16
Contactor100-C12 or 100-E12
Minimum enclosure volume1,655 in3

Frame A sets the terminal block to 3.3 mm2 (12 AWG) maximum and 0.8 mm2 (18 AWG) minimum at 1.4-1.6 N.m (12-14 lb-in). Those are the sizes the block accepts, not a recommendation for the motor lead, and the minimum is what decides whether a small motor cable can be landed directly or has to go through a junction.

Branch protection is outside the drive

The 4M does not provide branch short-circuit protection. It has to be installed with input fuses or an input circuit breaker, and national and local codes can add requirements on top of that. The manual states the point twice and adds an attention note about using only the recommended line fuses or breakers, because an improvised device voids the basis on which the drive was tested. This page documents 22F-B8P0N103.

Protection itemPublished value
Fuse15 A at 40 C (104 F), NEC basis
Self-protected combination controller140M-C2E-C16 or 140MT-C3E-C16
MCS contactor100-C12 or 100-E12
Minimum enclosure volume1,655 cubic inches
DC fuse position1000GH-025 where this row publishes it

The fuse class is part of the requirement, not a preference: BS88 parts 1 and 2 or EN60269-1 type gG for IEC installations, Class CC, T or J for UL. A fuse of the right amperage in the wrong class does not satisfy the table it came from.

Read as a whole row rather than as four separate lookups, the numbers for this string are 8.0 A output, 1.5 kW (2.0 HP) at 180-265 V, a 15 A fuse, a 140M-C2E-C16 or 140MT-C3E-C16 controller and a 100-C12 or 100-E12 contactor in at least 1,655 cubic inches. Those four move together: a panel built to a larger fuse than the row states is a panel whose protection no longer matches the drive it was tested with.

Emission character and the motor cable it allows

Character 11 reads 0, so this drive ships without integral EMC filter. The character does not change the rating, the frame or the terminal block; it changes the EMC environment the drive may be installed in and the motor cable length the manual permits.

Because no filter is inside the drive, an installation in a regulated environment needs an external unit in the panel: an S-type filter for a short lead or an L-type filter for a long one, with the allowances published for each. The 8.0 A rating and frame A are the same as the filtered string of the same rating; what changes is the cable length that can be certified, so a site survey that measures the motor lead comes before the order, not after it.

Filter routeSecond environmentFirst environment, unrestricted distribution
Integral filter, 240 V drive5 m1 m
Integral filter, 480 V drive10 msee the same table in 22F-UM001
External S-type filter5 m1 m
External L-type filter100 m25 m

An unfiltered drive on a long motor lead is a drive that fails an emissions check later, and the correction at that point is an external filter plus a retest rather than a catalog change. That is the practical reason a filtered code is ordered even where no regulation is quoted at the quotation stage. The catalog number covered on this page is 22F-B8P0N103.

Software limits that replace a larger catalog number

Output current is limited in software rather than by the frame. The current-limit parameter defaults to 1.5 times the drive rated amps and can be raised to 1.8 times, and the output-current monitor reads up to twice the rated amps. A drive one frame larger than the motor is therefore made safe for that motor by a parameter setting, and a machine that needs a slower ramp needs a different parameter rather tdocuments 22F-B8P0N103.

The two things a 4m does not contain. The 4M carries no branch short-circuit protection and no integral EMC filter on the unfiltered codes. Both have to be supplied around it: fuses or a circuit breaker upstream, and either the integral filter option or an external filter where the installation is regulated. A panel drawn around a bare 4M is a panel whose protection and emission compliance live in other line items.

Single-phase input, three-phase output. A 240 V single-phase 4M produces three-phase output from a single-phase supply, which is why small conveyors and fans in light-duty panels can use it at all. The motor is still a three-phase motor, and the input and output phase counts are two separate questions on this family.

Filter class decides the motor lead. The emission character does not change the rating, the frame or the terminals; it changes the environment the drive may be installed in and the motor cable length the manual allows. An integral 240 V filter is good for 5 m in the second environment, an integral 480 V filter for 10 m, an external S-type filter for 5 m, and an external L-type filter for 100 m outside the unrestricted first environment.

Frame letters and the wire that fits. Frames A, B and C set both the terminal block and the panel footprint: 12 AWG maximum on frame A, 8 AWG on frame B, 6 AWG on frame C. The minimum sizes matter as much as the maximum, because a small motor cable below the block minimum has to be landed through a junction rather than directly.

Protection device classes. The fuses are constrained by class as well as by current: BS88 parts 1 and 2 or EN60269-1 type gG for IEC installations, Class CC, T or J for UL. A fuse of the right amperage in the wrong class is not a substitute, and the manual states the acceptable classes in the same table as the size.

Panel thermal and mounting. Estimated watts loss is published per rating at rated load, rated speed and rated PWM, and it is a drive-only figure used in the panel thermal calculation. Panel mounting is the only form this family publishes, with a 1.9 mm minimum panel thickness and M4 scredocuments 22F-B8P0N103.

The 4M is the small-machine drive in this family, and the tell is in the protection table: it is the drive that does not carry branch short-circuit protection internally, so the panel around it has to supply it.

No price, lead time or lifecycle statement is implied. The rating, frame, terminal, protection and cable-length figures above are quoted from the PowerFlex 4M user manual, publication 22F-UM001, fodocuments 22F-B8P0N103.

Related catalog numbers in the 22F range

Twelve of the 34 22F records carried on this site, ordered by how close their codes sit to this one. This page is 22F-B8P0N103.

This listing is filed in the AB Drives & Motors group on plc-vip.com; the group index is AB Drives & Motors catalogue index, and the 22F-B8P0N103 page is one entry in it. It is the entry point used when a project list is assembled group by group.

Contact Details
PLC-VIP SHOP

Contact Person: Miss. linda

Tel: 00-852-65626925

Fax: 00-852-90164956

Send your inquiry directly to us (0 / 3000)