This page documents the 22F-B033N104, a PowerFlex 4M (bulletin 22F) drive in the 240 V three-phase class: 7.5 kW (10.0 HP), 33.0 A continuous output, frame C, IP20 panel mount, without integral EMC filter. The rating, the frame, the terminal sizes, the protection rows and the cable allowances are quoted from the PowerFlex 4M user manual 22F-UM001.
| Field | Value |
| Catalog number | 22F-B033N104 |
| Family | 22F - PowerFlex 4M, adjustable frequency AC drive, IP20 panel mount only |
| Voltage code (character 5) | B - 240 V three-phase |
| Rating code (characters 6-8) | 033 - 7.5 kW (10.0 HP), 33.0 A continuous |
| Frame | C |
| Enclosure (character 9) | N - IP20, the only enclosure form this family publishes |
| HIM position (character 10) | 1 |
| Emission class (character 11) | 0 - without integral EMC filter |
| Type (character 12) | 4 - carried, resolved in the option appendix rather than here |
| Positions 13-14 | not used on this string |
| Attribute | Value |
| Output current | 33.0 A continuous |
| Motor rating | 7.5 kW (10.0 HP) |
| Input window | 180-265 V |
| Frame | C |
| Terminal block | 13.3 mm2 (6 AWG) maximum, 3.3 mm2 (12 AWG) minimum, 2.7-3.2 N.m (24-28 lb-in) |
| Input kVA | 16.1 |
| Input current | 38.5 A |
| Fuse, 40 C NEC | 60 A |
| 140M / 140MT controller | 140M-F8E-C45 |
| Contactor | 100-C60 or 100-E52 |
| Minimum enclosure volume | 3,441 in3 |
Frame C sets the terminal block to 13.3 mm2 (6 AWG) maximum and 3.3 mm2 (12 AWG) minimum at 2.7-3.2 N.m (24-28 lb-in). Those are the sizes the block accepts, not a recommendation for the motor lead, and the minimum is what decides whether a small motor cable can be landed directly or has to go through a junction.
The 4M does not provide branch short-circuit protection. It has to be installed with input fuses or an input circuit breaker, and national and local codes can add requirements on top of that. The manual states the point twice and adds an attention note about using only the recommended line fuses or breakers, because an improvised device voids the basis on which the drive was tested. The catalog number covered on this page is 22F-B033N104.
| Protection item | Published value |
| Fuse | 60 A at 40 C (104 F), NEC basis |
| Self-protected combination controller | 140M-F8E-C45 |
| MCS contactor | 100-C60 or 100-E52 |
| Minimum enclosure volume | 3,441 cubic inches |
| DC fuse position | 1000GH-050 where this row publishes it |
The fuse class is part of the requirement, not a preference: BS88 parts 1 and 2 or EN60269-1 type gG for IEC installations, Class CC, T or J for UL. A fuse of the right amperage in the wrong class does not satisfy the table it came from.
Read as a whole row rather than as four separate lookups, the numbers for this string are 33.0 A output, 7.5 kW (10.0 HP) at 180-265 V, a 60 A fuse, a 140M-F8E-C45 controller and a 100-C60 or 100-E52 contactor in at least 3,441 cubic inches. Those four move together: a panel built to a larger fuse than the row states is a panel whose protection no longer matches the drive it was tested with.
Character 11 reads 0, so this drive ships without integral EMC filter. The character does not change the rating, the frame or the terminal block; it changes the EMC environment the drive may be installed in and the motor cable length the manual permits.
Because no filter is inside the drive, an installation in a regulated environment needs an external unit in the panel: an S-type filter for a short lead or an L-type filter for a long one, with the allowances published for each. The 33.0 A rating and frame C are the same as the filtered string of the same rating; what changes is the cable length that can be certified, so a site survey that measures the motor lead comes before the order, not after it.
| Filter route | Second environment | First environment, unrestricted distribution |
| Integral filter, 240 V drive | 5 m | 1 m |
| Integral filter, 480 V drive | 10 m | see the same table in 22F-UM001 |
| External S-type filter | 5 m | 1 m |
| External L-type filter | 100 m | 25 m |
An unfiltered drive on a long motor lead is a drive that fails an emissions check later, and the correction at that point is an external filter plus a retest rather than a catalog change. That is the practical reason a filtered code is ordered even where no regulation is quoted at the quotation stage. This page documents 22F-B033N104.
Output current is limited in software rather than by the frame. The current-limit parameter defaults to 1.5 times the drive rated amps and can be raised to 1.8 times, and the output-current monitor reads up to twice the rated amps. A drive one frame larger than the motor is therefore made safe for that motor by a parameter setting, and a machine that needs a slower ramp needs a different parameter rather than a different drive. The catalog number coveily:arial,helvetica,sans-serif;font-size:14px;color:#000000;">Current limit as a substitute for a different drive. Output current is limited in software: the current-limit parameter defaults to 1.5 times the drive rated amps and can be raised to 1.8 times, while the output-current monitor reads to twice the rated amps. A drive one frame larger than the motor is therefore made safe for that motor by a parameter, not by a second catalog number.
What the parameter number means over modbus. Over Modbus the register address equals the parameter number, so decimal 1 addresses d001 output frequency and decimal 109 addresses P109 acceleration time 1. A controls engineer commissioning from a PLC needs the parameter list rather than the catalog string, and the string is the part that has to be right before that work starts.
The panel mounting thickness. Panel mounting is the only mechanical form this family publishes, with a 1.9 mm (0.0747 in) minimum panel thickness and M4 (#8-32) screws at 1.56...1.96 N.m. That is thinner than the larger drive families expect, and it is the figure that decides whether the drive can sit on a machine frame instead of in a cabinet.
Reorder risk on the emission character. Two drives with the same rating and different character 11 are different products when the cable run is long. A spare ordered by rating alone can arrive unfiltered into an installation that was commissioned with a filter, and the mismatch shows up as an emission problem rather than as a wrong part number.
The two things a 4m does not contain. The 4M carries no branch short-circuit protection and no integral EMC filter on the unfiltered codes. Both have to be supplied around it: fuses or a circuit breaker upstream, and either the integral filter option or an external filter where the installation is regulated. A panel drawn around a bare 4M is a panel whose protection and emission compliance live in other line items.
Panel thermal and mounting. Estimated watts loss is published per rating at rated load, rated speed and rated PWM, and it is a drive-only figure used in the panel thermal calculation. Panel mounting is the only form this family publishes, with a 1.9 mm minimum panel thickness and M4 screws at 1.56...1.96 N.m. The catalog number coveily:arial,helvetica,sans-serif;font-size:14px;color:#000000;">This rating is a 240 V single-phase one, which is the type of product a small conveyor or a fan in a light-duty panel uses; it produces three-phase output from a single-phase supply, so the motor is a three-phase motor on a single-phase feed.
No price, lead time or lifecycle statement is implied. The rating, frame, terminal, protection and cable-length figures above are quoted from the PowerFlex 4M user manual, publication 22F-UM001, for this catalog number. The catalog number covelcmp>