Product Details:
Payment & Shipping Terms:
|
This page documents catalog number 22F-B025N104, a PowerFlex 4M (bulletin 22F) drive on the 240 V three-phase class, without integral EMC filter. The rating code in this string is not one whose published row appears in the drive ratings table reproduced for this family, so this page records what the string settles and keeps the missing numbers out rather than inferring them.
| Field | Value |
| Catalog number | 22F-B025N104 |
| Family | 22F - PowerFlex 4M |
| Voltage code (character 5) | B |
| Rating code (characters 6-8) | 025 |
| Enclosure (character 9) | N |
| HIM position (character 10) | 1 |
| Emission class (character 11) | 0 |
| Type (character 12) | 4 |
What the string settles is the voltage class, the mechanical form, the HIM position and the emission character. What it does not settle is the kW, the output current, the frame and the fuse, all of which come from the rating row for this code.
The 4M carries no branch short-circuit protection inside the drive. Any installation of this product needs input fuses or an input circuit breaker, sized from the rating row, and Bulletin 140M/140MT self-protected controllers are accepted upstream without fuses where the panel uses that route.
The emission character matters more than the rating on a reorder. An integral filter and an unfiltered drive of the same rating are different products with different cable allowances, and the published allowances run from 1 m in the first environment with unrestricted distribution to 100 m with an external L-type filter.
Frame letters A, B and C set the terminal block. Frame A accepts 3.3 mm2 (12 AWG) maximum and 0.8 mm2 (18 AWG) minimum at 1.4-1.6 N.m; frame B accepts 8.4 mm2 (8 AWG) at 1.6-1.9 N.m; frame C accepts 13.3 mm2 (6 AWG) at 2.7-3.2 N.m. The minimum sizes are what the block accepts, not recommendations, and a motor cable below that minimum is landed through a junction rather than directly.
Panel mounting is the only form this family publishes, and the mounting recommendation is a 1.9 mm (0.0747 in) minimum panel thickness with M4 (#8-32) screws at 1.56-1.96 N.m. That is a thinner panel than a 20B-class drive expects, and it is the number that decides whether the drive can go on a machine frame rather than in a cabinet.
The drive ratings table carries the kW, the output amps, the input window, the kVA, the input amps, the fuse, the 140M controller, the contactor, the minimum enclosure volume and the DC fuse positions for every published code. Reading one of them without the rest is what produces a panel that meets the motor current and fails the fuse-class or enclosure check.
The 4M limits output current in software rather than by the frame. The current-limit parameter defaults to 1.5 times the drive rated amps and can be raised to 1.8 times, and the output-current monitor reads up to twice the rated amps, so a drive larger than the motor is made safe for that motor by a parameter rather than by a second catalog number.
The same logic applies to the acceleration and deceleration ramps and to the maximum frequency, which are parameters rather than product variants. A machine that needs a slower ramp does not need a different drive, and a spare ordered on the assumption that it does is a spare that will be reprogrammed anyway.
Estimated watts loss is published per rating and is a drive-only figure at rated load, rated speed and rated PWM. It is what a panel thermal calculation uses, and it is the number that decides whether a sealed enclosure needs a fan, so the loss table is read before the enclosure is ordered rather than after the panel runs hot.
Panel mounting is the only mechanical form this family publishes, and the mounting recommendation is a 1.9 mm (0.0747 in) minimum panel thickness with M4 (#8-32) screws at 1.56-1.96 N.m. That is a thinner panel than the 20B-class drives expect, and it decides whether the drive can go on a machine frame rather than inside a cabinet.
No lifecycle statement and no price is implied on this page. The requirements quoted are from the PowerFlex 4M user manual, publication 22F-UM001.
No lifecycle statement and no price is implied. The rating, frame, terminal, protection and cable-length figures are quoted from the PowerFlex 4M user manual, publication 22F-UM001.
Parameter access follows the drive rather than the panel: over Modbus the register address equals the parameter number, so decimal 1 addresses d001 [Output Freq] and decimal 109 addresses P109 [Accel Time 1]. A controls engineer commissioning from a PLC therefore needs the parameter list, not the catalog string, and the string is the part that must be right before that work starts.
This page prints the six catalogue positions of a PowerFlex 4M drive and gives a meaning to none of them. The first table fills each position from what the other 22F records on this site print at the same position; the second is the rating ladder those records build, with this code left as a hole in the middle of it.
| Character position | This page prints | What the sibling records print for the same position |
| 5, voltage | B | B - 240 V three-phase input, on 22F-B017N103 |
| 6 to 8, rating | 025 | 017 - 3.7 kW (5.0 HP), 17.5 A and 024 - 11.0 kW (15.0 HP), 24.0 A, plus 2P5 - 0.4 kW (0.5 HP), 2.5 A |
| 9, enclosure | N | N - IP20 panel mount, the only enclosure form this family publishes |
| 10, HIM position | 1 | printed as 1 on all six 22F records, with no meaning given anywhere |
| 11, emission class | 0 | 0 - without integral EMC filter, 1 - with integral EMC filter |
| 12, type | 4 | 3 on the 240 V single-phase codes and on 22F-B017N103, 4 on the 480 V codes and on this one |
| Code on this site | Voltage class | Amperes | kW and Hp | Frame | A per kW |
| 22F-A2P5N103 | 240 V single phase | 2.5 A | 0.4 kW / 0.5 Hp | A | 6.3 |
| 22F-A4P2N103 | 240 V single phase | 4.2 A | not printed | not printed | - |
| 22F-B017N103 | 240 V three phase | 17.5 A | 3.7 kW / 5.0 Hp | B | 4.7 |
| 22F-B025N104, this page | 240 V three phase | 25 A by the same convention | not printed | not printed | - |
| 22F-D018N104 | 480 V three phase | 18.0 A | 7.5 kW / 10.0 Hp | C | 2.4 |
| 22F-D024N104 | 480 V three phase | 24.0 A | 11.0 kW / 15.0 Hp | C | 2.2 |
The digits are the amperes, and five of the six records prove it: 2P5 prints 2.5 A, 4P2 prints 4.2 A, 017 prints 17.5 A, 018 prints 18.0 A and 024 prints 24.0 A. So 025 is the 25 A size of a 240 V three-phase drive, and this page is the one page that prints neither the kW, the Hp nor the frame for it. The ladder itself shows the pattern that matters: 2.2 A per kW at 480 V, 4.7 at 240 V three-phase and 6.3 at 240 V single-phase, so the amperes a breaker sees follow the voltage class and not the motor size.
The type character is the one position the records contradict: 3 on the 240 V single-phase codes, 3 on the 240 V three-phase 017 record, 4 on the 480 V codes and 4 on this page at 240 V three-phase. So it does not follow voltage alone, and no record on this site translates it.
What this record does not settle: the kW and Hp for the 025 rating, the frame letter, the output frequency range, the input current, the weight and dimensions, the filter part number behind the emission character, the meaning of the HIM position and the type character, and any lifecycle field.
This page is a decode table with the meanings left out, which makes it the least useful page in a family that prints meanings everywhere else. The one thing it does settle is the size: 025 is 25 A on 240 V three phase, one step above the 017 record at 17.5 A and 3.7 kW. Everything else about the unit has to be read from its siblings.
Source: the six catalogue positions printed on this page and the values printed at the same six positions on the five other 22F records carried on this site. The A per kW figure is the printed amperes divided by the printed kW on each record.
Twelve of the 34 22F records this shop lists, chosen by code proximity so that the nearest options are one click away. This page is 22F-B025N104.
Group index: AB Drives & Motors. 22F-B025N104 is filed under that heading in the site's own product tree. It is the entry point used when a project list is assembled group by group.
Data sources: the rating and filter rows quoted on this page for 22F-B025N104 follow 22F-UM001 (PowerFlex 4M user manual) and 22-TD001 (PowerFlex 4 / PowerFlex 40 technical data); nothing here is inferred from the catalog string.