Allen Bradley PowerFlex 22F-A2P5N103 / 22FA2P5N103

China Allen Bradley PowerFlex 22F-A2P5N103 / 22FA2P5N103 supplier
Allen Bradley PowerFlex 22F-A2P5N103 / 22FA2P5N103 supplier Allen Bradley PowerFlex 22F-A2P5N103 / 22FA2P5N103 supplier Allen Bradley PowerFlex 22F-A2P5N103 / 22FA2P5N103 supplier Allen Bradley PowerFlex 22F-A2P5N103 / 22FA2P5N103 supplier Allen Bradley PowerFlex 22F-A2P5N103 / 22FA2P5N103 supplier Allen Bradley PowerFlex 22F-A2P5N103 / 22FA2P5N103 supplier Allen Bradley PowerFlex 22F-A2P5N103 / 22FA2P5N103 supplier Allen Bradley PowerFlex 22F-A2P5N103 / 22FA2P5N103 supplier Allen Bradley PowerFlex 22F-A2P5N103 / 22FA2P5N103 supplier Allen Bradley PowerFlex 22F-A2P5N103 / 22FA2P5N103 supplier Allen Bradley PowerFlex 22F-A2P5N103 / 22FA2P5N103 supplier Allen Bradley PowerFlex 22F-A2P5N103 / 22FA2P5N103 supplier Allen Bradley PowerFlex 22F-A2P5N103 / 22FA2P5N103 supplier Allen Bradley PowerFlex 22F-A2P5N103 / 22FA2P5N103 supplier Allen Bradley PowerFlex 22F-A2P5N103 / 22FA2P5N103 supplier

Large Image :  Allen Bradley PowerFlex 22F-A2P5N103 / 22FA2P5N103

Product Details:

Place of Origin: Made in CHINA
Brand Name: PLC Module
Certification: All goods we supply are 100% original factory sealed with 1 year warranty!
Model Number: Allen Bradley PowerFlex 22F-A2P5N103 / 22FA2P5N103

Payment & Shipping Terms:

Minimum Order Quantity: 1 /PCS
Price: $102.00 (USD/PCS)
Packaging Details: 100% original new
Delivery Time: IN STOCK; 4-6 weeks for ordering
Payment Terms: T/T, Western Union and Paypal.
Supply Ability: 5 PCS
Detailed Product Description

22F-A2P5N103

This page documents catalog number 22F-A2P5N103, a PowerFlex 4M (bulletin 22F) drive on the 240 V single-phase class: 0.4 kW (0.5 HP), 2.5 A continuous output, frame A, IP20 panel mount, the only enclosure form this family publishes, without integral EMC filter. The rating, frame, terminal sizes and protection figures are taken from the published PowerFlex 4M user manual rather than from a nameplate.

Decode and published rating

FieldValue
Catalog number22F-A2P5N103
Family22F - PowerFlex 4M adjustable frequency AC drive
Voltage code (character 5)A - 240 V single-phase input
Rating code (characters 6-8)2P5 - 0.4 kW (0.5 HP), 2.5 A
FrameA
Enclosure (character 9)N - IP20 panel mount, the only enclosure form this family publishes
HIM position (character 10)1
Emission class (character 11)0 - without integral EMC filter
Type (character 12)3 - carried, not translated on this page
Optional positions 13-14

Rating, frame and the input window

The published row for this code gives 2.5 A continuous output at 0.4 kW (0.5 HP) across a 180-265 V input window, in frame A. The manual also lists 1.6 kVA and 6.5 A on the input side for this row.

A 240 V single-phase drive produces three-phase output; the phase count on the input and the phase count on the output are two different questions on this family, and a drive bought for a single-phase panel still needs a three-phase motor.

Frame A sets the terminal block: maximum 3.3 mm2 (12 AWG), minimum 0.8 mm2 (18 AWG), at 1.4-1.6 N.m (12-14 lb-in). Those are the sizes the block accepts, not a recommendation, and the minimum is the one that decides whether a small motor cable can be landed directly or needs a junction.

Branch short-circuit protection is not inside the drive

The 4M does not provide branch short-circuit protection. It has to be installed with either input fuses or an input circuit breaker, and national and local codes can add requirements on top of that. The manual states the point twice and adds an attention note about using only the recommended line fuses or breakers, because an improvised device voids the basis on which the drive was tested.

For this rating the manual gives a 10 A fuse at 40 degrees C with NEC guidance, with 140M-C2E-C10 or 140MT-C3E-C10 as the self-protected combination controller and 100-C09 or 100-E09 as the MCS contactor, in a minimum enclosure volume of 1,655 cubic inches. The DC fuse positions are published too: 1000GH-016 for BR+/DC+ and DC-.

The fuses are constrained by class as well as size: BS88 parts 1 and 2 or EN60269-1 type gG for IEC installations, and Class CC, T or J for UL. The manual adds that Bulletin 140M/140MT controllers may sit upstream of the drive without fuses, which is the route that saves panel width when a self-protected controller is already in the design.

Filter character and the cable length it buys

Character 11 reads 0, so this drive ships without integral EMC filter. The emission character does not change the rating, the frame or the terminal block; it changes the EMC environment the drive can be installed in and the motor cable length the manual permits.

The published allowances separate the two filter routes: an integral filter on a 240 V drive is good for 5 m in the second environment and 1 m in the first environment with unrestricted distribution, an integral 480 V filter for 10 m in the second environment, an external S-type filter for 5 m and 1 m on the same split, and an external L-type filter for 100 m in the first two cases and 25 m in the unrestricted first environment.

Those numbers are the reason a filtered drive is ordered even when the panel is not in a regulated environment: an unfiltered drive with a long motor lead is a drive that fails an emissions test later, and the fix at that point is an external filter and a re-test rather than a catalogue change.

Load, loss and what the string leaves open

The estimated watts loss for this rating is published in the loss table of the manual; it is the figure a panel thermal calculation uses and it is a drive-only figure, not the motor or the enclosure.

Output current is limited in software rather than by the frame: the current-limit parameter defaults to 1.5 times the drive rated amps and can be raised to 1.8 times, and the output-current monitor reads up to twice the rated amps. A 4M therefore protects a motor that is smaller than its rating by a parameter setting rather than by a different catalog number.

The string does not settle the HIM, the communications option or the braking resistor. Type character 3 is carried rather than translated here, and the option appendix resolves the HIM and filter part numbers per code, which is the only safe route to a spare.

A 4M is often bought as a spare for a machine that already runs one, and the character that is easy to get wrong on a reorder is the emission character: a filtered and an unfiltered drive have the same rating but not the same cable allowance.

No lifecycle statement and no price is implied. The rating, frame, terminal, protection and cable-length figures are quoted from the PowerFlex 4M user manual, publication 22F-UM001.

Parameter access follows the drive rather than the panel: over Modbus the register address equals the parameter number, so decimal 1 addresses d001 [Output Freq] and decimal 109 addresses P109 [Accel Time 1]. A controls engineer commissioning from a PLC therefore needs the parameter list, not the catalog string, and the string is the part that must be right before that work starts.

The six 22F PowerFlex 4M records: rating, then protection

This record is placed on the six-record 22F PowerFlex 4M ladder carried on this site. The first table is the rating each record prints or declines to print; the second is the protection and enclosure that follows from it. Both quote only what the individual pages state, and a record whose page refers a field to 22F-UM001 is marked as not printed rather than filled in from a neighbouring rating.

Catalog numberVoltage classOutput currentRated powerFrameInput windowInput kVA / current
22F-A2P5N103A - 240 V single-phase2.5 A0.4 kW (0.5 HP)A180-265 V1.6 kVA / 6.5 A
22F-A4P2N103A - 240 V single-phase4.2 Anot printed - referred to 22F-UM001not printed180-265 V (class level)not printed
22F-A4P2N113A - 240 V single-phase4.2 Anot printed - referred to 22F-UM001not printed180-265 V (class level)not printed
22F-B017N103B - 240 V three-phase17.5 A3.7 kW (5.0 HP)B180-265 V8.8 kVA / 21.1 A
22F-D018N104D - 480 V three-phase18.0 A7.5 kW (10.0 HP)C340-528 V16.3 kVA / 19.5 A
22F-D024N104D - 480 V three-phase24.0 A11.0 kW (15.0 HP)C340-528 V21.7 kVA / 26.1 A

Protection and enclosure that follow. The line fuse is a function of the input current, and the enclosure volume is a function of the frame.

Catalog numberLine fuse at 40 C140M / 140MT upstreamContactorMin enclosure volume
22F-A2P5N10310 A140M-C2E-C10 / 140MT-C3E-C10100-C09 / 100-E091,655 in3
22F-A4P2N103not printed - referred to 22F-UM001not printednot printednot printed
22F-A4P2N113not printed - referred to 22F-UM001not printednot printednot printed
22F-B017N10335 A140M-D8E-C25 / 140MT-D9E-C25100-C23 / 100-E261,655 in3
22F-D018N10430 A140M-F8E-C25100-C23 / 100-E263,441 in3
22F-D024N10440 A140M-F8E-C32100-C30 / 100-E303,441 in3

Where this record sits: smallest rating in the batch, 2.5 A in frame A, and the only record whose input current is more than twice its output current - 6.5 A in against 2.5 A out.

The fuse is sized off the input current and not off the output rating. Reading the four records that print both, 6.5 A of input takes a 10 A fuse, 21.1 A takes 35 A, 19.5 A takes 30 A and 26.1 A takes 40 A - each roughly 1.5 times the input current. A buyer who sizes protection from the output amps of a single-phase drive lands at 2.5 A and a fuse far too small for a feed that actually draws 6.5 A.

What these pages do not carry: no enclosure dimensions, only the minimum volume in cubic inches, so the panel layout has to come from the manual; no drive weight; no efficiency, loss or thermal figure; no overload percentage for the thermal model; and on the two 4.2 A records no kW, HP, frame, kVA, input current, fuse, contactor or enclosure volume at all, because those pages deliberately refer the rating row to 22F-UM001 rather than reproduce it.

Only record in the batch that combines the smallest frame with the full protection row, and the only one whose DC fuse is 1000GH-016 - the other three that print a DC fuse all print 1000GH-050. Ten amps of line fuse for 2.5 A of output looks like a gross oversize until the input current is read: 6.5 A on a single-phase feed, and 10 A is roughly 1.5 times that.

Source: the decode tables and body text printed on the six 22F records on this site, which cite 22F-UM001 for the rating rows, the fuse and enclosure volumes; the output currents, kW and HP figures, input windows, kVA and input currents, terminal ranges, torques, fuse ratings, 140M/140MT and contactor part numbers, enclosure volumes and DC fuse numbers are quoted from the records that print them, and fields a record refers to the manual are shown as not printed.

Related catalog numbers in the 22F range

This page links twelve of the 34 22F records on this site; the closest rating codes come first. This page is 22F-A2P5N103.

For the surrounding range, open the AB Drives & Motors catalogue index — 22F-A2P5N103 is listed there beside the rest of the drive and motor group. Reach it directly if the suffix on this record still needs confirming against a sibling.