logo
Home ProductsAB Drives & Motors

Allen Bradley PowerFlex 22D-E4P2N104 / 22DE4P2N104

Customer Reviews
Welcome to PLC-VIP , Your online shop for Allen Bradley & Siemens PLC parts.

—— PLC-VIP.SHOP

We also wish to be able to continue doing good business with you and your company in the years to come. We are very thankful for that.

—— Rodrigo

I'm Online Chat Now

Allen Bradley PowerFlex 22D-E4P2N104 / 22DE4P2N104

China Allen Bradley PowerFlex 22D-E4P2N104 / 22DE4P2N104 supplier
Allen Bradley PowerFlex 22D-E4P2N104 / 22DE4P2N104 supplier Allen Bradley PowerFlex 22D-E4P2N104 / 22DE4P2N104 supplier Allen Bradley PowerFlex 22D-E4P2N104 / 22DE4P2N104 supplier Allen Bradley PowerFlex 22D-E4P2N104 / 22DE4P2N104 supplier Allen Bradley PowerFlex 22D-E4P2N104 / 22DE4P2N104 supplier Allen Bradley PowerFlex 22D-E4P2N104 / 22DE4P2N104 supplier Allen Bradley PowerFlex 22D-E4P2N104 / 22DE4P2N104 supplier Allen Bradley PowerFlex 22D-E4P2N104 / 22DE4P2N104 supplier Allen Bradley PowerFlex 22D-E4P2N104 / 22DE4P2N104 supplier Allen Bradley PowerFlex 22D-E4P2N104 / 22DE4P2N104 supplier Allen Bradley PowerFlex 22D-E4P2N104 / 22DE4P2N104 supplier Allen Bradley PowerFlex 22D-E4P2N104 / 22DE4P2N104 supplier Allen Bradley PowerFlex 22D-E4P2N104 / 22DE4P2N104 supplier Allen Bradley PowerFlex 22D-E4P2N104 / 22DE4P2N104 supplier Allen Bradley PowerFlex 22D-E4P2N104 / 22DE4P2N104 supplier

Large Image :  Allen Bradley PowerFlex 22D-E4P2N104 / 22DE4P2N104

Product Details:

Place of Origin: Made in CHINA
Brand Name: PLC Module
Certification: All goods we supply are 100% original factory sealed with 1 year warranty!
Model Number: Allen Bradley PowerFlex 22D-E4P2N104 / 22DE4P2N104

Payment & Shipping Terms:

Minimum Order Quantity: 1 /PCS
Price: $416.00 (USD/PCS)
Packaging Details: 100% original new
Delivery Time: IN STOCK; 4-6 weeks for ordering
Payment Terms: T/T, Western Union and Paypal.
Supply Ability: 5 PCS
Detailed Product Description

22D-E4P2N104

This page documents catalog number 22D-E4P2N104, a PowerFlex 40P drive on the 600 V three-phase class: 2.2 kW (3.0 HP), 4.2 A continuous output at 0-575 V output, frame B, N. The kW, current, input range, fuse, motor protector, contactor and enclosure-volume figures are taken from the published PowerFlex 40P user manual for this rating rather than from a nameplate.

Decode and published rating

FieldValue
Catalog number22D-E4P2N104
Family22D - PowerFlex 40P adjustable frequency AC drive
Voltage code (character 5)E - 600 V three-phase input
Rating code (characters 6-8)4P2 - 2.2 kW (3.0 HP), 4.2 A
FrameB
Enclosure (character 9)N - IP20, NEMA/UL Type Open panel mount
HIM position (character 10)1
Emission class (character 11)0 - internal EMC filter position
Version (character 12)4
Optional positions 13-14

Rating, input and the difference between them

The published row for this code gives 2.2 kW (3.0 HP) at 4.2 A continuous output on a 414-660 V AC input range, with a kVA figure the manual omits for this row and 5.2 A input on the input side where the manual lists them. Input current is lower than output current on a drive at full load, because the DC link carries the power at a different voltage; a panel wired and fused on the output amps is over-protected on the input, and one wired on the input amps is under-protected on the motor cable.

The output voltage ceiling is 0-575 V, which is the phase-to-phase output the drive synthesizes from the 414-660 V AC input. A 480 V class drive driving a 460 V motor is inside that ceiling; a 400 V motor on the same drive runs at a lower voltage limit, so the motor nameplate is checked rather than the drive code.

Branch protection and the panel bill of materials

The manual publishes one branch protection answer per rating rather than a range: a 10 A fuse for this code at 40 degrees C with NEC guidance, with 140M-D8E-B63 or 140MT-D9E-B63 listed as the self-protected combination controller and 100-C09 or 100-E09 as the recommended MCS contactor, in a minimum enclosure volume of 1,655 cubic inches.

On 22D-E4P2N104 the fuse types are constrained as well as the size: IEC installations use BS88 parts 1 and 2 or EN60269-1 type gG, and UL installations require Class CC, T or J fuses. Where the exact rating is not available the manual says to choose the next higher fuse rating, which is the opposite of the instinct that usually governs a panel.

For 22D-E4P2N104 two protection routes are published, and they are not equivalent: both inverse-time circuit breakers and the listed 140M/140MT self-protected combination controllers are acceptable for IEC installations, while UL installations accept inverse-time breakers and the specified 140M/140MT controllers, not an instantaneous-trip motor circuit protector on its own. A 140M selected for a UL panel is a listing question as well as a current question.

Enclosure, mounting and the mechanical characters

Character 9 reads N, which the manual defines as IP20, NEMA/UL Type Open panel mount, intended for a cabinet-mounted drive that relies on the enclosure around it for the working environment. The three forms are the same drive electrically: panel mount, flange mount and plate drive share one rating row, so a change of this character does not change the current, the fuse or the motor protector, it changes the drawing, the heat path and the panel space.

A flange mount moves the heatsink through the wall and leaves the control section inside the cabinet, which is how a drive is kept out of a wash-down area without putting the whole drive in a rated enclosure. A plate drive is supplied without a housing and is not an IP20 product in its own right: the machine builder supplies the enclosure and with it the environmental rating.

Input power conditions worth checking before the order

The manual lists supply conditions that change the installation rather than the drive: a line impedance below 1 percent reactance, a supply transformer above 120 kVA, power-factor correction capacitors on the line, and frequent interruptions or noise spikes above 6,000 V. The published correctives are a line reactor, an isolation transformer or a bus inductor, and the reactance and transformer-size conditions are called out for the 5.5 kW and 11 kW ratings in particular.

A fifth condition is electrical rather than mechanical: a phase-to-ground voltage above 125 percent of the normal line-to-line voltage requires either removing the MOV jumper to ground or fitting an isolation transformer with a grounded secondary. That is a site measurement, and it is the one item on the list a panel builder cannot see from the drive.

Control wiring and what the string leaves open

Digital I/O control wire is published as 0.750 mm2 (18 AWG) three-conductor shielded cable such as Belden 8770 where shielding is used, on a 300 V, 60 degrees C minimum insulation rating. Unshielded wire is acceptable where national or local code allows it, and the shielded option is what a drive in a panel with switching contactors usually needs.

The string does not settle the feedback device, the communications adapter or the braking resistor. The HIM position reads 1 and the emission class position reads 0, and this page carries them rather than translating them into part numbers, because the option appendix resolves them per code and a translation from the string alone produces a wrong spare.

The difference between two catalog numbers in the same frame is usually the enclosure character or the filter character, and those two change the panel drawing far more than the rating code does.

No lifecycle statement and no price is implied for 22D-E4P2N104. The rating, input range, fuse, motor protector, contactor, enclosure volume and control-wire figures are quoted from the PowerFlex 40P user manual, publication 22D-UM001.

Where this rating sits in the 600 V ladder

PowerFlex 40P is selected rating by rating rather than by frame: each code in the 600 V three-phase class carries its own current, its own branch fuse and its own listed motor protector, and the step to the next code changes all three at once. The rows below are the published values for the class this catalog number belongs to, with the kW and HP figures the manual prints alongside them.

Rating codekWHPOutput AFrameBranch fuse140M controller
22D-E1P70.751.01.7B6 A140M-C2E-B25 or 140MT-C3E-B25
22D-E3P01.52.03.0B6 A140M-C2E-B40 or 140MT-C3E-B40
22D-E4P22.23.04.2B10 A140M-D8E-B63 or 140MT-D9E-B63
22D-E6P64.05.06.6B15 A140M-D8E-C10 or 140MT-D9E-C10
22D-E9P95.57.59.9B20 A140M-D8E-C16 or 140MT-D9E-C16
22D-E0127.510.012.2C25 A140M-D8E-C16 or 140MT-D9E-C16

This code, 22D-E4P2, is row 3 of 6 in the class: 2.2 kW (3.0 HP) at 4.2 A continuous output in frame B, protected by a 10 A fuse with 140M-D8E-B63 or 140MT-D9E-B63 as the listed controller. The next row, 22D-E6P6, is 6.6 A in frame B, so a load that lands between the two belongs on the larger code unless the duty cycle leaves headroom in the smaller one. The row below, 22D-E3P0, is 3.0 A in frame B, so a motor between the two currents has no published row of its own in this class and lands on the larger code.

The frame boundary is the one place where the mechanical answer changes with the rating: 22D-E9P9 is the last row in frame B at a published minimum enclosure volume of 2,069 cubic inches and 22D-E012 is the first in frame C at 2,069. The two frames share the same minimum volume in this class, so a motor change that crosses the boundary does not resize the cabinet even though the frame character changes.

The fuse column is a ladder of its own and it does not follow the current in even steps: 6 A on 22D-E1P7, 6 A on 22D-E3P0, 10 A on 22D-E4P2, 15 A on 22D-E6P6, 20 A on 22D-E9P9, 25 A on 22D-E012. Where the exact rating is unavailable the manual instructs the next higher fuse, and the fuse class is constrained as well - BS88 parts 1 and 2 or EN60269-1 type gG for IEC, Class CC, T or J for UL - so a fuse bought on amperage alone is not a listed installation.

What the 22D-E4P2N104 table does not carry is the input current and the kVA figure for every row: the manual prints them for some ratings and omits them for others, and the omissions are listed as omissions here rather than filled with a neighbouring value. The frame, the fuse and the 140M controller, which is what a panel schedule actually needs, are complete for every row shown.

Related catalog numbers in the 22D range

Of the 47 22D records carried here, these twelve stand closest to this catalog number. This page is 22D-E4P2N104.

Site tree: the AB Drives & Motors index carries 22D-E4P2N104 together with the other entries of the drive and motor group, which is where a catalogue walk usually starts. Sibling codes of the same group are one click away from that page.

Contact Details
PLC-VIP SHOP

Contact Person: Miss. linda

Tel: 00-852-65626925

Fax: 00-852-90164956

Send your inquiry directly to us (0 / 3000)