Product Details:
Payment & Shipping Terms:
|
This page documents catalog number 22B-E9P9F104, a PowerFlex 40 drive: 600 V AC three-phase, 9.9 A, 5.5 kW (7.5 HP), enclosure F, frame C. The decode and every figure below come from the drive family's published selection and installation tables; the option positions the documentation does not resolve are named as unresolved rather than guessed.
| Field | Value |
| Catalog number | 22B-E9P9F104 |
| Family (characters 1-3) | 22B - PowerFlex 40 adjustable frequency AC drive |
| Voltage class (character 5) | E - 600 V AC three-phase |
| Input band as published | 500-600 V AC (414-660 V window) |
| Output as published | 0-575 V three-phase |
| Rating code (characters 6-8) | 9P9 - 9.9 A, 5.5 kW (7.5 HP) |
| Frame size | C |
| Enclosure (character 9) | F - IP20 flange mount |
| Emission class (character 11) | 0 - no integral filter (unfiltered drive) |
| Drive type (character 12) | 4 - the family notes that this position indicates drive type and that all PowerFlex 40 drives carry RS485 |
The 600 V three-phase class covers installations where 600 V is the distribution rather than a transformed 480 V. Seven codes span 1.7 A to 19 A and 0.75 to 11 kW, with an input window of 414 to 660 V and an output range of 0 to 575 V.
The currents in this class, 22B-E9P9F104 among them, are lower than the 480 V class at the same power, which is arithmetic rather than design: the same kilowatts at a higher voltage need fewer amps. A buyer comparing the two tables by current alone will misread the 600 V drives as smaller machines.
The enclosure character of 22B-E9P9F104 reads F, the IP20 flange-mount variant, where the heatsink passes through the back of the cabinet so the heat leaves the enclosure instead of being circulated inside it.
Flange mounting on 22B-E9P9F104 is a mechanical commitment rather than an accessory. The cut-out, the heatsink depth and the seal between drive and panel are fixed by the variant, and a cabinet built for an open drive cannot be converted by cutting a hole afterwards without losing the IP20 rating of the assembly.
On frame C of 22B-E9P9F104 the published power terminal block accepts 8.4 mm2 (8 AWG) maximum and 1.3 mm2 (16 AWG) minimum at 2.9-3.7 N-m (26-33 lb-in), and the I/O terminal block common to frames B and C accepts 1.3 mm2 (16 AWG) maximum and 0.2 mm2 (24 AWG) minimum at 0.5-0.8 N-m. The frame measures 130 x 260 x 180 mm and ships at 4.3 kg.
The emission character reads 0. At 1 the string describes a drive with the integral S-type EMC filter the family lists for this rating; at 0 it describes an unfiltered drive, and the EMC obligation moves to the installation. The manual also gives the cable lengths the two filter families allow: S type for at least 10 m in a Class A environment and 1 m in Class B, L type for at least 100 m in Class A and 5 m in Class B. A filter is not inferable from the power rating, only from this character, which is why 22B-E9P9F104 is read at that position before anything else.
The enclosure does not upgrade the drive; it carries the rating of the enclosure around it, and 22B-E9P9F104 is no exception. The manual states that the drive meets IP40, IP54 and IP65 for NEMA 1, 12, 4 and 4X only when installed inside an enclosure of like rating, which is the sentence that decides whether an open drive is acceptable in a given room.
Dynamic braking on 22B-E9P9F104 is a resistor selection rather than a drive setting: the manual lists 51 ohm, AK-R2-120P1K2 for this kW rating, and the resistors are rated for 5 percent duty cycle. The resistance changes with the rating rather than staying fixed, so a resistor carried over from a different size does not transfer.
Where the drive needs a line reactor or a DC bus inductor, the manual lists the Bulletin 1321-3R series and the MTE RB series by drive rating, and the larger ratings of the 480 V class are flagged as requiring an external DC bus inductor or AC line reactor rather than being usable bare. For 22B-E9P9F104 the reactor line therefore stays a bill-of-materials question rather than a commissioning note.
The string settles voltage class, output current, enclosure, filter and drive type. It does not settle the motor, the cable, the upstream protection or the duty, and on a drive of this size those four decide whether the installation works. 22B-E9P9F104 is the drive's capability; the installation around it is the engineer's.
Two drives of this family can share a current and a voltage and differ in enclosure or filter, so a spare order that quotes a rounded-off number can produce a unit that runs the motor and does not fit the panel. 22B-E9P9F104 is one of those strings, and quoting it in full is the discipline that prevents that.
In 22B-E9P9F104 the interface position reads 1. The 22B family carries an interface module code in that position, and every PowerFlex 40 drive is stated to include RS485 communication regardless of it, so the RS485 link is a property of the drive rather than of the option. On this page the 1 is not translated into a module type, because the selection table resolves it by rating and the position is not self-describing.
Commissioning a drive of this class starts with the two numbers the string does not carry: the motor nameplate current, which the drive must be limited to, and the acceleration the machine actually needs. On 22B-E9P9F104 the current limit is set from the motor nameplate rather than from the rating row, because a drive this small is usually protecting a motor rather than controlling a process.
No lifecycle statement and no price is implied. The rating rows, the voltage bands, the enclosure definitions, the terminal and frame data, the filter cable limits, the braking resistor selections and the reactor notes behind 22B-E9P9F104 are quoted from the drive family's published selection and installation tables.
Each code in this class is a separate published row rather than a step on a frame ladder: current, frame and braking resistor all move together, and only the enclosure and interface characters are free. The rows below carry the current and the resistor the manual lists for this class, which is what a spare order has to match.
| Rating code | kW | HP | Output A | Frame | Brake resistor |
|---|---|---|---|---|---|
| 22B-E1P7 | 0.75 | 1.0 | 1.7 | B | 120 ohm, AK-R2-360P500 |
| 22B-E3P0 | 1.5 | 2.0 | 3.0 | B | 120 ohm, AK-R2-360P500 |
| 22B-E4P2 | 2.2 | 3.0 | 4.2 | B | 82 ohm, AK-R2-120P1K2 |
| 22B-E6P6 | 4.0 | 5.0 | 6.6 | B | 82 ohm, AK-R2-120P1K2 |
| 22B-E9P9 | 5.5 | 7.5 | 9.9 | C | 51 ohm, AK-R2-120P1K2 |
| 22B-E012 | 7.5 | 10.0 | 12.2 | C | 51 ohm, AK-R2-120P1K2 |
| 22B-E019 | 11.0 | 15.0 | 19.0 | C | 51 ohm, AK-R2-120P1K2 with two resistors in parallel |
This code is row 5 of 7 in the class: 5.5 kW (7.5 HP) at 9.9 A continuous output on frame C, with a 51 ohm, AK-R2-120P1K2 braking resistor. The enclosure character on this number reads IP20 flange mount, which is one of the forms the family publishes for this rating: it changes the housing and the drawing, not the current, the frame or the resistor. The next code, 22B-E012, is 12.2 A on frame C. The code below, 22B-E6P6, stops at 6.6 A, so a motor between the two currents belongs on this rating rather than on the smaller one.
Crossing from frame B to frame C is the one step that changes the cabinet: 22B-E6P6 sits at 100 x 180 x 136 mm and 2.2 kg, 22B-E9P9 at 130 x 260 x 180 mm and 4.3 kg, and the power terminal grows from 5.3 mm2 (10 AWG) maximum at 1.7-2.2 N-m (16-19 lb-in) to 8.4 mm2 (8 AWG) maximum at 2.9-3.7 N-m (26-33 lb-in). A panel drawing that was right for the smaller code is wrong for the larger one by that much, before the motor cable is even considered.
Three-phase in and three-phase out, as on 22B-E9P9F104, means the input and output currents are close but not equal, and neither is a substitute for the other. A panel built on the output amps under-fuses the input; a panel built on the input amps leaves the motor cable outside the protection the drive was listed for.
The ladder does not carry the branch fuse or the motor protector for 22B-E9P9F104, and that is not an omission of this page: the family resolves both per rating in its installation tables. A bill of materials assembled from the selection ladder alone leaves two lines for the panel builder, and both are protection decisions rather than accessories.
Of the 112 22B records carried here, these twelve stand closest to this catalog number. This page is 22B-E9P9F104.
Site tree: the AB Drives & Motors index carries 22B-E9P9F104 together with the other entries of the drive and motor group, which is where a catalogue walk usually starts.
Sources. Rockwell publishes the PowerFlex 40 user manual as 22B-UM001, and the technical data for the PowerFlex 4 and 40 ranges as 22-TD001. The ratings, terminal designations and ordering characters quoted on this page for 22B-E9P9F104 follow those two publications.