Product Details:
Payment & Shipping Terms:
|
This page documents catalog number 22B-E3P0C104, a PowerFlex 40 drive: 600 V AC three-phase, 3 A, 1.5 kW (2 HP), enclosure C, frame B. The decode and every figure below come from the drive family's published selection and installation tables; the option positions the documentation does not resolve are named as unresolved rather than guessed.
| Field | Value |
| Catalog number | 22B-E3P0C104 |
| Family (characters 1-3) | 22B - PowerFlex 40 adjustable frequency AC drive |
| Voltage class (character 5) | E - 600 V AC three-phase |
| Input band as published | 500-600 V AC (414-660 V window) |
| Output as published | 0-575 V three-phase |
| Rating code (characters 6-8) | 3P0 - 3 A, 1.5 kW (2 HP) |
| Frame size | B |
| Enclosure (character 9) | C - IP66, NEMA/UL Type 4X |
| Emission class (character 11) | 0 - no integral filter (unfiltered drive) |
| Drive type (character 12) | 4 - the family notes that this position indicates drive type and that all PowerFlex 40 drives carry RS485 |
The 600 V three-phase class covers installations where 600 V is the distribution rather than a transformed 480 V. Seven codes span 1.7 A to 19 A and 0.75 to 11 kW, with an input window of 414 to 660 V and an output range of 0 to 575 V.
The currents in this class, 22B-E3P0C104 among them, are lower than the 480 V class at the same power, which is arithmetic rather than design: the same kilowatts at a higher voltage need fewer amps. A buyer comparing the two tables by current alone will misread the 600 V drives as smaller machines.
The enclosure character of 22B-E3P0C104 reads C, which the family defines as IP66 and NEMA/UL Type 4X: a sealed, panel-mount drive that can stand on the machine rather than inside a cabinet, removing the enclosure from the project scope.
There is a published limit that decides whether this variant can be ordered at all. The family states that IP66 and NEMA/UL Type 4X drives are not available in frame C ratings, so a rating sitting on frame C has no IP66 version and a specification asking for both has asked for something the family does not build.
On frame B of 22B-E3P0C104 the published power terminal block accepts 5.3 mm2 (10 AWG) maximum and 1.3 mm2 (16 AWG) minimum at 1.7-2.2 N-m (16-19 lb-in), and the I/O terminal block common to frames B and C accepts 1.3 mm2 (16 AWG) maximum and 0.2 mm2 (24 AWG) minimum at 0.5-0.8 N-m. The frame measures 100 x 180 x 136 mm and ships at 2.2 kg.
The emission character reads 0. At 1 the string describes a drive with the integral S-type EMC filter the family lists for this rating; at 0 it describes an unfiltered drive, and the EMC obligation moves to the installation. The manual also gives the cable lengths the two filter families allow: S type for at least 10 m in a Class A environment and 1 m in Class B, L type for at least 100 m in Class A and 5 m in Class B. A filter is not inferable from the power rating, only from this character, which is why 22B-E3P0C104 is read at that position before anything else.
The enclosure does not upgrade the drive; it carries the rating of the enclosure around it, and 22B-E3P0C104 is no exception. The manual states that the drive meets IP40, IP54 and IP65 for NEMA 1, 12, 4 and 4X only when installed inside an enclosure of like rating, which is the sentence that decides whether an open drive is acceptable in a given room.
Dynamic braking on 22B-E3P0C104 is a resistor selection rather than a drive setting: the manual lists 120 ohm, AK-R2-360P500 for this kW rating, and the resistors are rated for 5 percent duty cycle. The resistance changes with the rating rather than staying fixed, so a resistor carried over from a different size does not transfer.
Where the drive needs a line reactor or a DC bus inductor, the manual lists the Bulletin 1321-3R series and the MTE RB series by drive rating, and the larger ratings of the 480 V class are flagged as requiring an external DC bus inductor or AC line reactor rather than being usable bare. For 22B-E3P0C104 the reactor line therefore stays a bill-of-materials question rather than a commissioning note.
The string settles voltage class, output current, enclosure, filter and drive type. It does not settle the motor, the cable, the upstream protection or the duty, and on a drive of this size those four decide whether the installation works. 22B-E3P0C104 is the drive's capability; the installation around it is the engineer's.
Two drives of this family can share a current and a voltage and differ in enclosure or filter, so a spare order that quotes a rounded-off number can produce a unit that runs the motor and does not fit the panel. 22B-E3P0C104 is one of those strings, and quoting it in full is the discipline that prevents that.
In 22B-E3P0C104 the interface position reads 1. The 22B family carries an interface module code in that position, and every PowerFlex 40 drive is stated to include RS485 communication regardless of it, so the RS485 link is a property of the drive rather than of the option. On this page the 1 is not translated into a module type, because the selection table resolves it by rating and the position is not self-describing.
Commissioning a drive of this class starts with the two numbers the string does not carry: the motor nameplate current, which the drive must be limited to, and the acceleration the machine actually needs. On 22B-E3P0C104 the current limit is set from the motor nameplate rather than from the rating row, because a drive this small is usually protecting a motor rather than controlling a process.
No lifecycle statement and no price is implied. The rating rows, the voltage bands, the enclosure definitions, the terminal and frame data, the filter cable limits, the braking resistor selections and the reactor notes behind 22B-E3P0C104 are quoted from the drive family's published selection and installation tables.
The class is selected by current, not by frame, and the table below shows why: two codes can share a frame and differ by a factor of two in current, and the resistor changes even inside one frame. The rows are the published values for this class; the resistor cell is the part the manual names for that kilowatt rating.
| Rating code | kW | HP | Output A | Frame | Brake resistor |
|---|---|---|---|---|---|
| 22B-E1P7 | 0.75 | 1.0 | 1.7 | B | 120 ohm, AK-R2-360P500 |
| 22B-E3P0 | 1.5 | 2.0 | 3.0 | B | 120 ohm, AK-R2-360P500 |
| 22B-E4P2 | 2.2 | 3.0 | 4.2 | B | 82 ohm, AK-R2-120P1K2 |
| 22B-E6P6 | 4.0 | 5.0 | 6.6 | B | 82 ohm, AK-R2-120P1K2 |
| 22B-E9P9 | 5.5 | 7.5 | 9.9 | C | 51 ohm, AK-R2-120P1K2 |
| 22B-E012 | 7.5 | 10.0 | 12.2 | C | 51 ohm, AK-R2-120P1K2 |
| 22B-E019 | 11.0 | 15.0 | 19.0 | C | 51 ohm, AK-R2-120P1K2 with two resistors in parallel |
This code is row 2 of 7 in the class: 1.5 kW (2.0 HP) at 3.0 A continuous output on frame B, with a 120 ohm, AK-R2-360P500 braking resistor. The enclosure character on this number reads IP66, NEMA/UL Type 4X, which is one of the forms the family publishes for this rating: it changes the housing and the drawing, not the current, the frame or the resistor. The next code, 22B-E4P2, is 4.2 A on frame B. The code below, 22B-E1P7, stops at 1.7 A, so a motor between the two currents belongs on this rating rather than on the smaller one.
The mechanical step in this ladder is the B to C frame change, at 22B-E6P6 (100 x 180 x 136 mm, 2.2 kg) against 22B-E9P9 (130 x 260 x 180 mm, 4.3 kg). The terminal block follows the frame rather than the current: 5.3 mm2 (10 AWG) maximum at 1.7-2.2 N-m (16-19 lb-in) on B, 8.4 mm2 (8 AWG) maximum at 2.9-3.7 N-m (26-33 lb-in) on C, so the wire size and the torque value both move with the frame.
The class is three-phase in and three-phase out - 22B-E3P0C104 included - so input and output current differ only by the DC link and the efficiency. A panel fused on the output amps is over-protected on the input side, and one fused on the input amps is under-protected on the motor cable, which is why the two columns are read separately in the manual rather than taken from one row of this table.
What the ladder leaves out for 22B-E3P0C104 is the upstream protection. Fuse size and motor protector are per-rating entries in the installation tables, so two drives with the same frame and different current codes take different protection - the frame tells you the terminal, never the fuse.
Twelve of the 112 22B records this shop lists, chosen by code proximity so that the nearest options are one click away. This page is 22B-E3P0C104.
Group index: AB Drives & Motors. 22B-E3P0C104 is filed under that heading in the site's own product tree. Reach it directly if the suffix on this record still needs confirming against a sibling.
Sources. Rockwell publishes the PowerFlex 40 user manual as 22B-UM001, and the technical data for the PowerFlex 4 and 40 ranges as 22-TD001. The ratings, terminal designations and ordering characters quoted on this page for 22B-E3P0C104 follow those two publications.