Product Details:
Payment & Shipping Terms:
|
This page documents catalog number 22B-D4P0C104, a PowerFlex 40 drive: 480 V AC three-phase, 4 A, 1.5 kW (2 HP), enclosure C, frame B. The decode and every figure below come from the drive family's published selection and installation tables; the option positions the documentation does not resolve are named as unresolved rather than guessed.
| Field | Value |
| Catalog number | 22B-D4P0C104 |
| Family (characters 1-3) | 22B - PowerFlex 40 adjustable frequency AC drive |
| Voltage class (character 5) | D - 480 V AC three-phase |
| Input band as published | 380-480 V AC (342-528 V window) |
| Output as published | 0-460 V three-phase |
| Rating code (characters 6-8) | 4P0 - 4 A, 1.5 kW (2 HP) |
| Frame size | B |
| Enclosure (character 9) | C - IP66, NEMA/UL Type 4X |
| Emission class (character 11) | 0 - no integral filter (unfiltered drive) |
| Drive type (character 12) | 4 - the family notes that this position indicates drive type and that all PowerFlex 40 drives carry RS485 |
The 480 V three-phase class is the volume class of this family: eight codes from 1.4 A to 24 A and 0.4 to 11 kW, an input window of 342 to 528 V and an output range of 0 to 460 V.
One statement in this class is easy to miss and expensive to forget on 22B-D4P0C104. The family publishes 35 percent of rated current for single-phase operation of a 480 V drive, so a unit ordered for a three-phase machine and connected to a single-phase feed does not deliver its nameplate current.
The enclosure character of 22B-D4P0C104 reads C, which the family defines as IP66 and NEMA/UL Type 4X: a sealed, panel-mount drive that can stand on the machine rather than inside a cabinet, removing the enclosure from the project scope.
There is a published limit that decides whether this variant can be ordered at all. The family states that IP66 and NEMA/UL Type 4X drives are not available in frame C ratings, so a rating sitting on frame C has no IP66 version and a specification asking for both has asked for something the family does not build.
On frame B of 22B-D4P0C104 the published power terminal block accepts 5.3 mm2 (10 AWG) maximum and 1.3 mm2 (16 AWG) minimum at 1.7-2.2 N-m (16-19 lb-in), and the I/O terminal block common to frames B and C accepts 1.3 mm2 (16 AWG) maximum and 0.2 mm2 (24 AWG) minimum at 0.5-0.8 N-m. The frame measures 100 x 180 x 136 mm and ships at 2.2 kg.
The emission character reads 0. At 1 the string describes a drive with the integral S-type EMC filter the family lists for this rating; at 0 it describes an unfiltered drive, and the EMC obligation moves to the installation. The manual also gives the cable lengths the two filter families allow: S type for at least 10 m in a Class A environment and 1 m in Class B, L type for at least 100 m in Class A and 5 m in Class B. A filter is not inferable from the power rating, only from this character, which is why 22B-D4P0C104 is read at that position before anything else.
The enclosure does not upgrade the drive; it carries the rating of the enclosure around it, and 22B-D4P0C104 is no exception. The manual states that the drive meets IP40, IP54 and IP65 for NEMA 1, 12, 4 and 4X only when installed inside an enclosure of like rating, which is the sentence that decides whether an open drive is acceptable in a given room.
Dynamic braking on 22B-D4P0C104 is a resistor selection rather than a drive setting: the manual lists 97 ohm, AK-R2-360P500 for this kW rating, and the resistors are rated for 5 percent duty cycle. The resistance changes with the rating rather than staying fixed, so a resistor carried over from a different size does not transfer.
Where the drive needs a line reactor or a DC bus inductor, the manual lists the Bulletin 1321-3R series and the MTE RB series by drive rating, and the larger ratings of the 480 V class are flagged as requiring an external DC bus inductor or AC line reactor rather than being usable bare. For 22B-D4P0C104 the reactor line therefore stays a bill-of-materials question rather than a commissioning note.
The string settles voltage class, output current, enclosure, filter and drive type. It does not settle the motor, the cable, the upstream protection or the duty, and on a drive of this size those four decide whether the installation works. 22B-D4P0C104 is the drive's capability; the installation around it is the engineer's.
Two drives of this family can share a current and a voltage and differ in enclosure or filter, so a spare order that quotes a rounded-off number can produce a unit that runs the motor and does not fit the panel. 22B-D4P0C104 is one of those strings, and quoting it in full is the discipline that prevents that.
In 22B-D4P0C104 the interface position reads 1. The 22B family carries an interface module code in that position, and every PowerFlex 40 drive is stated to include RS485 communication regardless of it, so the RS485 link is a property of the drive rather than of the option. On this page the 1 is not translated into a module type, because the selection table resolves it by rating and the position is not self-describing.
Commissioning a drive of this class starts with the two numbers the string does not carry: the motor nameplate current, which the drive must be limited to, and the acceleration the machine actually needs. On 22B-D4P0C104 the current limit is set from the motor nameplate rather than from the rating row, because a drive this small is usually protecting a motor rather than controlling a process.
No lifecycle statement and no price is implied. The rating rows, the voltage bands, the enclosure definitions, the terminal and frame data, the filter cable limits, the braking resistor selections and the reactor notes behind 22B-D4P0C104 are quoted from the drive family's published selection and installation tables.
A PowerFlex 40 order is a single rating code, and the code fixes the current, the frame and the braking resistor at once. The ladder below is the published row set for this supply class, with the resistor the manual names for each kilowatt rating; a resistor carried over from a smaller drive is a different part, not an adequate one.
| Rating code | kW | HP | Output A | Frame | Brake resistor |
|---|---|---|---|---|---|
| 22B-D1P4 | 0.4 | 0.5 | 1.4 | B | 97 ohm, AK-R2-360P500 |
| 22B-D2P3 | 0.75 | 1.0 | 2.3 | B | 97 ohm, AK-R2-360P500 |
| 22B-D4P0 | 1.5 | 2.0 | 4.0 | B | 97 ohm, AK-R2-360P500 |
| 22B-D6P0 | 2.2 | 3.0 | 6.0 | B | 97 ohm, AK-R2-120P1K2 |
| 22B-D010 | 4.0 | 5.0 | 10.5 | C | 77 ohm, AK-R2-120P1K2 |
| 22B-D012 | 5.5 | 7.5 | 12.0 | C | 55 ohm, AK-R2-120P1K2 |
| 22B-D017 | 7.5 | 10.0 | 17.0 | C | 39 ohm, AK-R2-120P1K2 |
| 22B-D024 | 11.0 | 15.0 | 24.0 | C | 24 ohm, AK-R2-120P1K2 with two resistors in parallel |
This code is row 3 of 8 in the class: 1.5 kW (2.0 HP) at 4.0 A continuous output on frame B, with a 97 ohm, AK-R2-360P500 braking resistor. The enclosure character on this number reads IP66, NEMA/UL Type 4X, which is one of the forms the family publishes for this rating: it changes the housing and the drawing, not the current, the frame or the resistor. The next code, 22B-D6P0, is 6.0 A on frame B. The code below, 22B-D2P3, stops at 2.3 A, so a motor between the two currents belongs on this rating rather than on the smaller one.
The frame boundary is where the mechanical answer changes rather than the electrical one: 22B-D6P0 is the last code on frame B at 100 x 180 x 136 mm and 2.2 kg, and 22B-D010 is the first on frame C at 130 x 260 x 180 mm and 4.3 kg. The power terminal moves from 5.3 mm2 (10 AWG) maximum at 1.7-2.2 N-m (16-19 lb-in) to 8.4 mm2 (8 AWG) maximum at 2.9-3.7 N-m (26-33 lb-in) as well, so the motor cable and not only the rail space has to be re-checked at that step.
Three-phase in and three-phase out, as on 22B-D4P0C104, means the input and output currents are close but not equal, and neither is a substitute for the other. A panel built on the output amps under-fuses the input; a panel built on the input amps leaves the motor cable outside the protection the drive was listed for.
Two columns a panel schedule wants for 22B-D4P0C104 are deliberately absent: branch-circuit protection and the motor protector. They are resolved per rating in the installation tables rather than in this selection ladder, so a quote built from the ladder alone arrives with the current and the frame settled and the fuse holder still open.
This page links twelve of the 112 22B records on this site; the closest rating codes come first. This page is 22B-D4P0C104.
For the surrounding range, open the AB Drives & Motors catalogue index — 22B-D4P0C104 is listed there beside the rest of the drive and motor group. Reach it directly if the suffix on this record still needs confirming against a sibling.
Sources. Rockwell publishes the PowerFlex 40 user manual as 22B-UM001, and the technical data for the PowerFlex 4 and 40 ranges as 22-TD001. The ratings, terminal designations and ordering characters quoted on this page for 22B-D4P0C104 follow those two publications.