Product Details:
Payment & Shipping Terms:
|
This page documents catalog number 22B-B033H204, a PowerFlex 40 drive: 240 V AC three-phase, 33 A, 7.5 kW (10 HP), enclosure H, frame C. The decode and every figure below come from the drive family's published selection and installation tables; the option positions the documentation does not resolve are named as unresolved rather than guessed.
| Field | Value |
| Catalog number | 22B-B033H204 |
| Family (characters 1-3) | 22B - PowerFlex 40 adjustable frequency AC drive |
| Voltage class (character 5) | B - 240 V AC three-phase |
| Input band as published | 200-240 V AC |
| Output as published | 0-230 V three-phase |
| Rating code (characters 6-8) | 033 - 33 A, 7.5 kW (10 HP) |
| Frame size | C |
| Enclosure (character 9) | H - IP20 replacement plate drive |
| Emission class (character 11) | 0 - no integral filter (unfiltered drive) |
| Drive type (character 12) | 4 - the family notes that this position indicates drive type and that all PowerFlex 40 drives carry RS485 |
The 240 V three-phase class is the widest low-voltage option in the family, seven codes from 2.3 A to 33 A and 0.4 to 7.5 kW. A three-phase supply on this class delivers the full published rating, which is why it is the class used where a 240 V distribution already exists and the machine needs a compact drive rather than a panel.
The class crosses a frame boundary inside itself: the ratings up to 17.5 A sit on frame B and the 24 A and 33 A ratings move to frame C, with the terminal block, wire range and torque changing with the frame.
The enclosure character reads H, which the drive's selection table gives as the IP20 replacement plate drive variant, a form intended for a drive that replaces an existing unit on a mounting plate rather than for a new panel build.
A replacement plate variant is a fit-to-existing-hardware decision before it is an electrical one. The mounting interface and the space it occupies are properties of this variant, so a substitution toward or away from it changes the mechanical installation even when the rating is identical.
On frame C the published power terminal block accepts 8.4 mm2 (8 AWG) maximum and 1.3 mm2 (16 AWG) minimum at 2.9-3.7 N-m (26-33 lb-in), and the I/O terminal block common to frames B and C accepts 1.3 mm2 (16 AWG) maximum and 0.2 mm2 (24 AWG) minimum at 0.5-0.8 N-m. The frame measures 130 x 260 x 180 mm and ships at 4.3 kg.
The emission character reads 0. At 1 the string describes a drive with the integral S-type EMC filter the family lists for this rating; at 0 it describes an unfiltered drive, and the EMC obligation moves to the installation. The manual also gives the cable lengths the two filter families allow: S type for at least 10 m in a Class A environment and 1 m in Class B, L type for at least 100 m in Class A and 5 m in Class B. A filter is not inferable from the power rating, only from this character, which is why 22B-B033H204 is read at that position before anything else.
The enclosure does not upgrade the drive; it carries the rating of the enclosure around it, and 22B-B033H204 is no exception. The manual states that the drive meets IP40, IP54 and IP65 for NEMA 1, 12, 4 and 4X only when installed inside an enclosure of like rating, which is the sentence that decides whether an open drive is acceptable in a given room.
Dynamic braking on this rating is a resistor selection rather than a drive setting: the manual lists 10 ohm, AK-R2-030P1K2 for this kW rating, and the resistors are rated for 5 percent duty cycle. The resistance changes with the rating rather than staying fixed, so a resistor carried over from a different size does not transfer.
Where the drive needs a line reactor or a DC bus inductor, the manual lists the Bulletin 1321-3R series and the MTE RB series by drive rating, and the larger ratings of the 480 V class are flagged as requiring an external DC bus inductor or AC line reactor rather than being usable bare. For 22B-B033H204 the reactor line therefore stays a bill-of-materials question rather than a commissioning note.
The string settles voltage class, output current, enclosure, filter and drive type. It does not settle the motor, the cable, the upstream protection or the duty, and on a drive of this size those four decide whether the installation works. 22B-B033H204 is the drive's capability; the installation around it is the engineer's.
Two drives of this family can share a current and a voltage and differ in enclosure or filter, so a spare order that quotes a rounded-off number can produce a unit that runs the motor and does not fit the panel. 22B-B033H204 is one of those strings, and quoting it in full is the discipline that prevents that.
The interface position in this string reads 2. The family carries an interface module code in that position, and every PowerFlex 40 drive is stated to include RS485 communication regardless of it, so the RS485 link is a property of the drive rather than of the option. The 2 value is not translated into a module type on this page, because the selection table resolves it per rating and the position is not self-describing.
Commissioning a drive of this class starts with the two numbers the string does not carry: the motor nameplate current, which the drive must be limited to, and the acceleration the machine actually needs. On 22B-B033H204 the current limit is set from the motor nameplate rather than from the rating row, because a drive this small is usually protecting a motor rather than controlling a process.
No lifecycle statement and no price is implied. The rating rows, the voltage bands, the enclosure definitions, the terminal and frame data, the filter cable limits, the braking resistor selections and the reactor notes behind 22B-B033H204 are quoted from the drive family's published selection and installation tables.
Each code in this class is a separate published row rather than a step on a frame ladder: current, frame and braking resistor all move together, and only the enclosure and interface characters are free. The rows below carry the current and the resistor the manual lists for this class, which is what a spare order has to match.
| Rating code | kW | HP | Output A | Frame | Brake resistor |
|---|---|---|---|---|---|
| 22B-B2P3 | 0.4 | 0.5 | 2.3 | B | 48 ohm, AK-R2-091P500 |
| 22B-B5P0 | 0.75 | 1.0 | 5.0 | B | 48 ohm, AK-R2-091P500 |
| 22B-B8P0 | 1.5 | 2.0 | 8.0 | B | 48 ohm, AK-R2-091P500 |
| 22B-B012 | 2.2 | 3.0 | 12.0 | B | 32 ohm, AK-R2-047P500 |
| 22B-B017 | 3.7 | 5.0 | 17.5 | B | 19 ohm, AK-R2-047P500 |
| 22B-B024 | 5.5 | 7.5 | 24.0 | C | 13 ohm, AK-R2-030P1K2 |
| 22B-B033 | 7.5 | 10.0 | 33.0 | C | 10 ohm, AK-R2-030P1K2 |
This code is row 7 of 7 in the class: 7.5 kW (10.0 HP) at 33.0 A continuous output on frame C, with a 10 ohm, AK-R2-030P1K2 braking resistor. The enclosure character on this number reads IP20 replacement plate drive, which is one of the forms the family publishes for this rating: it changes the housing and the drawing, not the current, the frame or the resistor. The code below, 22B-B024, stops at 24.0 A, so a motor between the two currents belongs on this rating rather than on the smaller one.
Crossing from frame B to frame C is the one step that changes the cabinet: 22B-B017 sits at 100 x 180 x 136 mm and 2.2 kg, 22B-B024 at 130 x 260 x 180 mm and 4.3 kg, and the power terminal grows from 5.3 mm2 (10 AWG) maximum at 1.7-2.2 N-m (16-19 lb-in) to 8.4 mm2 (8 AWG) maximum at 2.9-3.7 N-m (26-33 lb-in). A panel drawing that was right for the smaller code is wrong for the larger one by that much, before the motor cable is even considered.
The class is three-phase in and three-phase out, so input and output current differ only by the DC link and the efficiency. A panel fused on the output amps is over-protected on the input side, and one fused on the input amps is under-protected on the motor cable, which is why the two columns are read separately in the manual rather than taken from one row of this table.
The ladder does not carry the branch fuse or the motor protector, and that is not an omission of this page: the family resolves both per rating in its installation tables. A bill of materials assembled from the selection ladder alone leaves two lines for the panel builder, and both are protection decisions rather than accessories.
Twelve of the 112 22B records carried on this site, ordered by how close their codes sit to this one. This page is 22B-B033H204.
This listing is filed in the AB Drives & Motors group on plc-vip.com; the group index is AB Drives & Motors catalogue index, and the 22B-B033H204 page is one entry in it. Reach it directly if the suffix on this record still needs confirming against a sibling.
Sources. Rockwell publishes the PowerFlex 40 user manual as 22B-UM001, and the technical data for the PowerFlex 4 and 40 ranges as 22-TD001. The ratings, terminal designations and ordering characters quoted on this page for 22B-B033H204 follow those two publications.