Product Details:
Payment & Shipping Terms:
|
| 1784-CF128 | CompactFlash Card | IN STOCK |
| 1784-CP | PLC-3 Communication Cable | IN STOCK |
| 1784-CP10 | PLC-5 Communication Cable | IN STOCK |
| 1784-CP11 | PLC-5 Communication Cable | IN STOCK |
| 1784-CP14 | SLC Communication Cable | IN STOCK |
| 1784-CP6 | PLC-5 Communication Cable | IN STOCK |
| 1784-CP7 | PLC-5 Communication Adaptor | IN STOCK |
| 1784-CP8 | PLC-5 Communication Adaptor | IN STOCK |
| 1784-PCC1 | ControlNet Communication Cable | IN STOCK |
| 1784-PCD1 | DeviceNet Communication Cable | IN STOCK |
| 1784-PCIC | ControlNet PC Card | IN STOCK |
| 1784-PCICS | ControlNet PC Card | IN STOCK |
| 1784-PCIDS | DeviceNet PC Card | IN STOCK |
| 1784-PCM2 | DIRECT CONNECT CBL 15PIN D SHELL PLC-2 | IN STOCK |
| 1784-PCM4 | Data Highway Plus Cable | IN STOCK |
| 1784-PCM5 | Data Highway Plus Cable | IN STOCK |
| 1784-PCM6 | Data Highway Plus Cable | IN STOCK |
| 1784-PKTCS | ControlNet 1.5 PC Card | IN STOCK |
| 1784-PKTX | Data Highway Plus PC Card | IN STOCK |
| 1784-PKTXD | Data Highway Plus PC Card | IN STOCK |
| 1784-SD1 | Secure Digital Card | IN STOCK |
| 1784-SD2 | Secure Digital Card | IN STOCK |
| 1784-U2CN | PC ControlNet to USB Port Cable | IN STOCK |
| 1784-U2DHP | Data Highway Plus Cable | IN STOCK |
| 1784-U2DN | DeviceNet Interface Cable | IN STOCK |
The 1784-U2DHP connects a computer's USB port to a Data Highway Plus network, so an engineer can go online with PLC-5 and SLC 5/04 processors from a modern laptop that has no PCMCIA slot. It replaces both the 1784-PCMK communication card and the 1784-PCM6 cable as a single assembly.
The cable is a node on the DH+ link in its own right: it takes a station number from 0...77 octal, set by the first packet RSLinx Classic sends after power is applied. That means it can be inserted on a live network at an unused address without disturbing existing nodes - useful when a line is running and a fault has to be diagnosed now.
Compatibility is specific: PLC-5 processors except the Classic PLC-5 family (PLC-5/10, /12, /15, /25) and SLC 5/04 processors. Communication on the link requires the RSLinx Classic DF1 serial 1770-KF2/1785-KE driver, and the device driver is installed from the 1784_u2dhp.inf file supplied with the cable.
|
Brand Name
|
PLC Module
|
|
Cable Type
|
interface
|
|
Cat Num
|
1784-U2DHP
|
|
Class
|
Inter connect cable
|
|
Connection
|
Data Highway Plus to PC USB port
|
|
Controls-Indicators
|
Module, USB and network status indicators |
|
Data Highway Plus Controller Interfaces
|
USB-to-Data Highway Plus Adapter
|
|
Form Factor
|
IP30 enclosure, 76.2 x 50.8 x 25.4 mm |
|
Host Interface
|
USB
|
|
Power Supply
|
USB bus power, 5.0V DC (5.25V DC max), 125 mA |
|
Standard
|
CE,C-TICK,CUL,KC,UL
|
|
Sub Brand
|
Data Highway Plus
|
|
Type
|
USB-to-DH+ programming cable (replaces 1784-PCMK + 1784-PCM6) |
|
UNSPSC
|
43201404
|
Power comes from the USB bus: 5.00 V dc, 5.25 V dc maximum, 125 mA, 1.575 W maximum dissipation - no external supply is needed and nothing has to be wired into the cabinet. Enclosure rating is IP30, overall size 76.2 x 50.8 x 25.4 mm (3 x 2 x 1 in.).
Isolation between DH+ and USB is 30 V continuous, basic insulation type, type tested at 500 V ac for 60 s. The DH+ port carries wiring category 2. Surge immunity on the DH+ port is ±2 kV line-earth (common mode) per IEC 61000-4-5, EFT/B ±2 kV at 5 kHz, and conducted RF 10 V rms from 150 kHz...80 MHz; radiated RF immunity is 10 V/m from 80...2700 MHz. Emissions are CISPR 11 Group 1, Class A.
Operating temperature 0...55 °C (32...131 °F), nonoperating -10...85 °C. Relative humidity 5...95% noncondensing, nonoperating shock 1000 mm (3.28 ft) per IEC 60068-2-27, ESD immunity 8 kV air discharges. The unit is intended for overvoltage Category II applications up to 2000 m altitude without derating.
We Could Supply Full Range Of PLC Module.
If you find the PLC Module part that you are looking for, pls Skype / Email us for a quote.
Two practical points. First, each cable you connect to the same PC gets its own COM port, so a workshop with several cables should record which COM port maps to which cable. Second, when several 1784-U2DHP cables are used on one computer, the driver must be configured per cable - RSLinx Classic presents them as separate DH+ interfaces.
The cable is also supported by Frontline's NetDecoder traffic analyzer, which makes it usable as a capture point rather than only as a programming path.
One more field detail: the cable is a programming and diagnostic path, not a permanent network component - it is powered from the PC's USB port, so it disappears from the DH+ link when the laptop is unplugged. Where a permanent DH+ connection between controllers is required, that belongs to the 1756-DHRIO or 1770-KF2 class of modules, not to this cable.
All figures on this page are from publication 1784-IN045C-EN-P (May 2010).
Same-family catalog numbers: 1784-U2CN, 1784-U2DN. Each of those catalogue numbers has its own stock page on this store; this page covers what differs in the 1784 family.
PLC-5 and SLC 5/04 processors, and the DH+ cabling that this adapter attaches to, are listed on our Allen-Bradley PLC-5 Systems and Allen-Bradley SLC 500 Systems 1747 category pages. Stock and lead time: sales@plc-vip.com.