Product Details:
Payment & Shipping Terms:
|
| 1784-CF128 | CompactFlash Card | IN STOCK |
| 1784-CP | PLC-3 Communication Cable | IN STOCK |
| 1784-CP10 | PLC-5 Communication Cable | IN STOCK |
| 1784-CP11 | PLC-5 Communication Cable | IN STOCK |
| 1784-CP14 | SLC Communication Cable | IN STOCK |
| 1784-CP6 | PLC-5 Communication Cable | IN STOCK |
| 1784-CP7 | PLC-5 Communication Adaptor | IN STOCK |
| 1784-CP8 | PLC-5 Communication Adaptor | IN STOCK |
| 1784-PCC1 | ControlNet Communication Cable | IN STOCK |
| 1784-PCD1 | DeviceNet Communication Cable | IN STOCK |
| 1784-PCIC | ControlNet PC Card | IN STOCK |
| 1784-PCICS | ControlNet PC Card | IN STOCK |
| 1784-PCIDS | DeviceNet PC Card | IN STOCK |
| 1784-PCM2 | DIRECT CONNECT CBL 15PIN D SHELL PLC-2 | IN STOCK |
| 1784-PCM4 | Data Highway Plus Cable | IN STOCK |
| 1784-PCM5 | Data Highway Plus Cable | IN STOCK |
| 1784-PCM6 | Data Highway Plus Cable | IN STOCK |
| 1784-PKTCS | ControlNet 1.5 PC Card | IN STOCK |
| 1784-PKTX | Data Highway Plus PC Card | IN STOCK |
| 1784-PKTXD | Data Highway Plus PC Card | IN STOCK |
| 1784-SD1 | Secure Digital Card | IN STOCK |
| 1784-SD2 | Secure Digital Card | IN STOCK |
| 1784-U2CN | PC ControlNet to USB Port Cable | IN STOCK |
| 1784-U2DHP | Data Highway Plus Cable | IN STOCK |
| 1784-U2DN | DeviceNet Interface Cable | IN STOCK |
The 1784-CF128 is a 128 MB industrial CompactFlash card for ControlLogix 5560 controllers - the larger of the two cards the platform accepts, the other being the 64 MB 1784-CF64. It sits in the controller's CompactFlash socket and provides nonvolatile storage: the project image, and from firmware version 16 onward, a file system for recipes, logs and other user data.
What it actually buys you is survival across a power loss and a battery failure. A controller's program lives in RAM and is held by the battery while de-energised; the card holds the stored image independently of the battery, and the controller can load from it at power-up. On a plant where batteries are replaced on a schedule, the card is the second line of defence.
Capacity selection is a simple decision: 128 MB against 64 MB, both accepted by the 5560 controllers, both transparent to the programming software. The card is not a performance device - access times are in the tens of milliseconds per command - it is a persistence device, and a project image is measured in single-digit megabytes, so either card holds many images.
|
Application
|
ControlLogix 5560 (1756-L6x) and 1768 CompactLogix controllers; RSLogix 5000 v11 or later |
|
Brand Name
|
PLC Module
|
|
Capacity
|
128MB
|
|
Cat Num
|
1784-CF128
|
|
Functions
|
User Program and Data Storage
|
|
Mounting
|
CompactFlash socket in the controller; stores firmware, project image and user files (nonvolatile memory) |
|
Standard
|
CE,C-TICK,GOST,KC
|
|
Sub Brand
|
ControlLogix
|
|
Temperature Rating
|
0-60 C
|
|
Type
|
Industrial CompactFlash memory card, 128 MB, FAT16 pre-formatted by Allen-Bradley |
|
UNSPSC
|
32151703
|
Compatibility: ControlLogix 5560 controllers with RSLogix 5000 software version 11 or later, and 1768 CompactLogix controllers. It does not fit ControlLogix 5570/5580 controllers, which take SD cards (1784-SD1/SD2) - the memory-card file system changed with the platform, and versions 17...20 use CompactFlash while version 21 and later use SD.
File system evolution on this card: with software version 11 the card only saved project image files through the NVS (nonvolatile storage) feature; version 12 added firmware and project image files; version 16 extended it to a file system able to store values, recipes and log data, accessed by program instructions in 450-byte chunks.
Practical spare: a card is cheap insurance against a controller failure, because the image can be carried to a replacement 5560 controller in the same rack position. What the card cannot do is substitute for a firmware match - the stored revision and the controller's firmware must be compatible, and a card from a newer project revision will refuse to load on an older controller. Labelling the card with the project revision is the habit that makes the spare usable.
Formatting: Allen-Bradley cards arrive pre-formatted to FAT16 and need no preparation. A card can be formatted with a PC card reader or from the programming software, but formatting erases it - the correct sequence is to format, then store the image. During a Store, all communications to the controller drop, I/O connections close temporarily, and removing the card mid-store can corrupt the stored image. A store can take minutes, and that window is a real production constraint, not a footnote.
We Could Supply Full Range Of PLC Module.
If you find the PLC Module part that you are looking for, pls Skype / Email us for a quote.
Protected: the stored image and user files, independent of the battery. Not protected: anything that was only in RAM and never stored, and the wall-clock time if the battery is dead - a fresh card does not restore date/time. The practical routine is store after any program change, note the revision stored, and keep the card in the controller rather than in a drawer.
Third-party cards: CompactFlash cards from other vendors will physically fit, and the platform documentation is explicit that using non-Allen-Bradley cards is done at the user's risk. On a production controller that risk is a corrupt image discovered at the worst moment, which is why the 1784-CF128 is specified by catalog number rather than by capacity.
Specifications and compatibility are from publication LOGIX-AP007, Memory Card Usability on Logix5000 Controllers, and the nonvolatile memory card programming manual, 1756-PM017.
ControlLogix controllers, memory cards and CompactFlash spares are listed on our category page. Availability: sales@plc-vip.com.