| 1784-CF128 | CompactFlash Card | IN STOCK |
| 1784-CP | PLC-3 Communication Cable | IN STOCK |
| 1784-CP10 | PLC-5 Communication Cable | IN STOCK |
| 1784-CP11 | PLC-5 Communication Cable | IN STOCK |
| 1784-CP14 | SLC Communication Cable | IN STOCK |
| 1784-CP6 | PLC-5 Communication Cable | IN STOCK |
| 1784-CP7 | PLC-5 Communication Adaptor | IN STOCK |
| 1784-CP8 | PLC-5 Communication Adaptor | IN STOCK |
| 1784-PCC1 | ControlNet Communication Cable | IN STOCK |
| 1784-PCD1 | DeviceNet Communication Cable | IN STOCK |
| 1784-PCIC | ControlNet PC Card | IN STOCK |
| 1784-PCICS | ControlNet PC Card | IN STOCK |
| 1784-PCIDS | DeviceNet PC Card | IN STOCK |
| 1784-PCM2 | DIRECT CONNECT CBL 15PIN D SHELL PLC-2 | IN STOCK |
| 1784-PCM4 | Data Highway Plus Cable | IN STOCK |
| 1784-PCM5 | Data Highway Plus Cable | IN STOCK |
| 1784-PCM6 | Data Highway Plus Cable | IN STOCK |
| 1784-PKTCS | ControlNet 1.5 PC Card | IN STOCK |
| 1784-PKTX | Data Highway Plus PC Card | IN STOCK |
| 1784-PKTXD | Data Highway Plus PC Card | IN STOCK |
| 1784-SD1 | Secure Digital Card | IN STOCK |
| 1784-SD2 | Secure Digital Card | IN STOCK |
| 1784-U2CN | PC ControlNet to USB Port Cable | IN STOCK |
| 1784-U2DHP | Data Highway Plus Cable | IN STOCK |
| 1784-U2DN | DeviceNet Interface Cable | IN STOCK |
The 1784-PKTX is a PCI network interface card that connects a PC to PLC-5 and SLC controllers over Data Highway Plus or DH-485, and can act as a remote I/O scanner. One channel, selectable between DH+ and DH-485, with the remote I/O scanner capability available on that channel.
Its reason to exist is the installed base: a plant with PLC-5 and SLC 5/04 controllers programs and troubleshoots them over DH+, and a PC without this card has no path to that network. The card is also the bridge for SoftLogix and for reaching ControlLogix through a 1756-DHRIO module - which makes it the tool of choice for a migration project that still has to talk to the old network while the new one is being built.
It is a universal PCI card: keyed for either 3.3 V or 5 V signalling, and it will sit in a 64-bit slot while using 32-bit operation. Plug and Play means no IRQ or base-address switches - the BIOS assigns the 4 KB dual-port memory window at boot, which is the detail that matters when several cards compete for address space in an older industrial PC.
|
Brand Name
|
PLC Module
|
|
Card Type
|
PCI universal card (PCI 2.3), one channel, active node on DH+ or DH-485, remote I/O scanner capable |
|
Cat Num
|
1784-PKTX
|
|
Class
|
PCI bus network interface card; 4 KB dual-port memory window; Plug and Play, no IRQ or address switches |
|
Communication Ports
|
CH 1A 3-pin Phoenix for DH+ / remote I/O; CH 1C 6-pin Phoenix for DH-485 |
|
Controls-Indicators
|
Operating Network Status
|
|
Form Factor
|
None (open-style)
|
|
Host Interface
|
PCI Bus
|
|
Mounting
|
PCI Computer Slot
|
|
Number Of Channels
|
1
|
|
Power Supply
|
From the PCI slot; 1784-PKTXD reference 800 mA at 5V DC, 4.0 W dissipation |
|
Special Features
|
scanner capability
|
|
Standard
|
CE,C-TICK,CUL,GOST,KC,UL
|
|
Sub Brand
|
Data Highway Plus
|
|
Type
|
PCI Bus Communication Card
|
|
UNSPSC
|
43201404
|
DH+ rates and distances: 57.6 kbit/s to 3,048 m (10,000 ft), 115.2 kbit/s to 1,524 m (5,000 ft), 230.4 kbit/s to 762 m (2,500 ft). DH-485: 1,200...19,200 bit/s to 1,219 m (4,000 ft). Remote I/O uses the same distances as DH+, at 57.6/115.2/230.4 kbit/s.
Termination: DH+ needs 150 Ω at 57.6 kbit/s and 115.2 kbit/s, or 82 Ω at 230.4 kbit/s, at both ends of the link; DH-485 needs no terminating resistor on the card but must be terminated at both ends of the network, and a CP14 cable used as the last node carries a termination switch. The card ships with both 82 Ω and 150 Ω resistors and with the DH+/RIO and DH-485 mating connectors.
System limits: up to four PKTx cards in one computer, each identified by jumpers (JP3 and the second identification jumper); one diagnostic/status LED per channel. Operating 0...60 °C, storage -40...+85 °C, 5...95% non-condensing, 2 g vibration at 10...500 Hz, isolation tested to 500 V ac for 60 s, wiring category 2 on the communication ports.
Software path: the RSLinx PKTx driver for DH+ and DH-485 in Windows, or the 1784-DP4 and 6001-RIO development packages for non-Windows driver work. Not every RSLinx or controller combination supports 115.2 and 230.4 kbit/s, so confirm the rate is supported before setting it - a card that appears deaf is often simply set faster than the rest of the link.
We Could Supply Full Range Of PLC Module.
If you find the PLC Module part that you are looking for, pls Skype / Email us for a quote.
One channel or two: the 1784-PKTX has one channel, usable on either DH+ or DH-485; the 1784-PKTXD has two, allowing a card to sit on a DH+ network and a DH-485 network at the same time, with remote I/O scanner capability only on channel 1. A workstation that must bridge the two networks needs the D part; a programming station on a single DH+ link does not.
Migration pattern that uses this card well: keep an industrial PC with a 1784-PKTX on the existing DH+ trunk for PLC-5 and SLC diagnostics, and add a 1756-DHRIO in the new ControlLogix rack to bring that traffic into EtherNet/IP. The card then retires when the last DH+ device does, which is a plan rather than a surprise.
Specifications are from publication 1784-UM527, 1784-PKTx Network Interface Card User Manual. Cable and termination practice from publication 1770-6.2.2, Data Highway/Data Highway Plus/Data Highway-485 Cable Installation Manual.
Same-family catalog numbers: 1784-PKTCS, 1784-PKTXD. Each of those catalogue numbers has its own stock page on this store; this page covers what differs in the 1784 family.
PLC-5 and SLC 500 controllers, DH+ interface modules and programming cables are listed on our Allen-Bradley PLC-5 and SLC 500 1747 category pages. Legacy spares: sales@plc-vip.com.