Product Details:
Payment & Shipping Terms:
|
| 1761-L10BWA | MicroLogix 1000 10 Point Controller | IN STOCK |
| 1761-L10BWB | MicroLogix 1000 10 Point Controller | IN STOCK |
| 1761-L10BXB | MicroLogix 1000 10 Point Controller | IN STOCK |
| 1761-L16AWA | MicroLogix 1000 16 Point Controller | IN STOCK |
| 1761-L16BBB | MicroLogix 1000 16 Point Controller | IN STOCK |
| 1761-L16BWA | MicroLogix 1000 16 Point Controller | IN STOCK |
| 1761-L16BWB | MicroLogix 1000 16 Point Controller | IN STOCK |
| 1761-L16NWA | MicroLogix 1000 16 Point Controller | IN STOCK |
| 1761-L16NWB | MicroLogix 1000 16 Point Controller | IN STOCK |
| 1761-L20AWA-5A | MicroLogix 1000 20 Point Controller | IN STOCK |
| 1761-L20BWA-5A | MicroLogix 1000 20 Point Controller | IN STOCK |
| 1761-L20BWB-5A | MicroLogix 1000 20 Point Controller | IN STOCK |
| 1761-L32AAA | MicroLogix 1000 32 Point Controller | IN STOCK |
| 1761-L32AWA | MicroLogix 1000 32 Point Controller | IN STOCK |
| 1761-L32BBB | MicroLogix 1000 32 Point Controller | IN STOCK |
| 1761-L32BWA | MicroLogix 1000 32 Point Controller | IN STOCK |
| 1761-L32BWB | MicroLogix 1000 32 Point Controller | IN STOCK |
| 1761-NET-AIC | MicroLogix and SLC Communication Adaptor | IN STOCK |
| 1761-NET-DNI | MicroLogix and SLC Communication Adaptor | IN STOCK |
| 1761-NET-ENI | MicroLogix and SLC Communication Adaptor | IN STOCK |
| 1761-NET-ENIW | MicroLogix and SLC Communication Adaptor | IN STOCK |
The 1761-L32AWA is the largest of the MicroLogix 1000 packaged controllers: 20 ac inputs, 12 relay outputs, and an 85...264 V ac supply in one 200 mm brick that carries its own power supply, input circuits, output circuits and processor.
Its input side reads 120 V ac directly - 79...132 V ac at 47...63 Hz - so pushbuttons, limit switches, float switches and 120 V ac relay contacts wire straight into the controller with no interposing relay. Outputs are dry relay contacts rated for the same ac voltages, which keeps a 120 V ac panel entirely ac end to end. The alternative in the same product line, 1761-L32BWA, reads 24 V dc inputs instead.
It is a fixed-configuration controller: no expansion bus, no plug-in I/O. That is the trade for the price and the 200 x 73 x 80 mm footprint. When a machine needs more than 32 points or a mix of analog, the 1762-equipped MicroLogix 1200 or the 1764 MicroLogix 1500 is the next step up.
|
Brand Name
|
PLC Module
|
|
Cat Num
|
1761-L32AWA
|
|
Class
|
controller
|
|
Communication
|
DF1
|
|
Depth
|
73 mm
|
|
Display
|
No
|
|
Enclosure
|
IP20
|
|
Height
|
80 mm
|
|
Input Signal
|
120V AC (79...132V AC, 47...63 Hz), 20 points |
|
Interface
|
RS-232
|
|
Memory
|
1K EEPROM (737 instruction words / 437 data words) |
|
Mounting
|
DIN Rail, Panel Mount
|
|
Number Of Channels
|
20 I/P, 12 O/P |
|
Operating Temperature
|
0... 55 ?C (32...131 ?F)
|
|
Output Signal
|
Relay, 12 points |
|
Power Supply
|
85...264V AC, 47...63 Hz |
|
Special Features
|
Built-in EEPROM
|
|
Standard
|
CE,CSA,C-TICK,GOST,KC,MARINE
|
|
Sub Brand
|
MicroLogix 1000
|
|
Type
|
Controller
|
|
UNSPSC
|
32151705
|
|
Width
|
200 mm
|
The 20 ac inputs are specified with an on-state current of 5.0 mA at 79 V ac and 47 Hz, 12.0 mA nominal at 120 V ac and 60 Hz, and 16.0 mA maximum at 132 V ac and 63 Hz; off-state is 0...20 V ac with 2.5 mA maximum leakage and nominal impedance of 12 kΩ at 50 Hz and 10 kΩ at 60 Hz. Inrush is 250 mA maximum, which the publication notes can be reduced to 35 mA by putting a 6.8 kΩ 5 W resistor in series with the input - at the cost of raising the on-state threshold to 92 V ac. On a panel with many identical 120 V ac pilot devices, that resistor is the difference between a clean input and a tripped upstream device.
The 12 relay poles are rated 240 V ac at 7.5 A make / 0.75 A break with 2.5 A continuous (1800 VA / 180 VA), 120 V ac at 15 A make / 1.5 A break, 125 V dc at 0.22 A make / 1.0 A break at 28 VA, and 24 V dc at 28 VA with a 2.0 A continuous limit; dc make/break values come from dividing 28 VA by the applied voltage. Current per controller is 1440 VA and per common 8.0 A, off-state leakage is 0 mA, response is 10 ms maximum, and mechanical life is 20,000,000 cycles.
Supply and memory: 85...264 V ac at 47...63 Hz, 24 VA at 120 V ac and 29 VA at 240 V ac, 30 A inrush for 8 ms, 50,000 power cycles minimum, isolation 1,500 V ac. Program memory is 1 K EEPROM - approximately 737 instruction words and 437 data words - so this controller suits relay-replacement logic, not data-heavy recipes. The built-in RS-232 port runs DF1; dimensions 200 x 73 x 80 mm, terminal screw torque 0.9 N·m maximum, 0...55 °C, IP20.
We Could Supply Full Range Of PLC Module.
If you find the PLC Module part that you are looking for, pls Skype / Email us for a quote.
Typical use is a standalone machine or a small process skid that has to run on 120 V ac control voltage with a fixed point count: conveyors, pumps, mixers, packaging heads. Because there is no expansion, the point count must be checked against the drawing before ordering - 20 in and 12 out is the hard ceiling.
Supporting items for this platform include the 1761-CBL-PM02 programming cable and 1761-NET-AIC for DH-485, and the 1761-NET-ENI/ENIW Ethernet interface if the controller has to join a network. All specifications here are from the MicroLogix 1000 installation instructions, publication 1761-IN001D-EN-P (June 2015), and the 1761-UM003 user manual.
Same-family catalog numbers: 1761-L32AAA, 1761-L32BBB, 1761-L32BWA, 1761-L32BWB. Each of those catalogue numbers has its own stock page on this store; this page covers what differs in the 1761 family.
The rest of the 10, 16, 20 and 32-point MicroLogix 1000 range is on our Allen-Bradley MicroLogix 1000 1761 category page. Quotes: sales@plc-vip.com.